tablas para calculo instalaciones

Post on 01-Oct-2015

24 Views

Category:

Documents

8 Downloads

Preview:

Click to see full reader

DESCRIPTION

Tablas Para Calculo Instalacione

TRANSCRIPT

  • RangodeAutomticos:

    1x2x3xCalibredeloscables:

    CALIBREDECABLESDEFASEPORCAPACIDADDECORRIENTE

    COBREAISLADO600VTHHNTHWN90GRADOS

    CALIBREAWGoKCM

    CANALIZACION(A)

    12 3010 408 556 754 952 1301* 1501/0 1702/0 1953/0** 2254/0 260250 290300 320350 350400 380500 430

    *Slosefabricaenaluminio**Slosefabricaencobre

    NoIndustriales

    15203040506070100

    Industriales15 125 50020 150 60030 175 70040 200 80050 250 90060 300 100070 350 1200100 400 1500

    1800

    CONDUCTORENTRADA

    CONDUCTORDETIERRA

    2oMENOR 81o1/0 62/0o3/0 4

    4/0a300KCM 2350a600KCM 1/0650a1000KCM 2/0SOBRE1000KCM 3/0

    CONDUCTORDETIERRA

    CALIBREAGWOKCM NEUTRO

    12 1210 108 106 84 62 41 21/0 22/0 1/03/0 1/04/0 2/0250 2/0300 3/0350 4/0400 4/0500 300

    NEUTROS

    15 112,5 63020 150 70030 225 80040 300 100075 400 1200

    500 1500

    TRANSFORMADORES(KVA)

  • ESTATABLASEUTILIZATENIENDOENCUENTAELNUMERODECONDUCTORESACTIVOS

    #CONDUTORES%CAPACIDADDE

    CORRIENTE

    1A3 100%4A6 80%7A24 70%25A42 60%

    43OMAS 50%

    CONSTANTESDEREGULACIONPARACABLESSUBTERRANEOSDEBTCua208VREDTRIFASICAENDUCTO

    CONDUCTORCuCONSTANTE(%/KVAMETRO)

    x10^4

    14 194.052

    12 122.643

    10 77.44350

    8 49.21170

    6 31.2320

    4 20.1401

    2 13.0761

    1 10.64260

    1/0 8.64741

    2/0 7.09272

    3/0 5.82849

    4/0 4.81759

    250 4.2767

    300 3.73479

    350 3.35979

    400 3.04584

    500 2.65629

    TABLA7.5.6DECODENSATEMPERATURACONDUCTOR45GRADOSFACTORDEPOTENCIA0.9FRECUENCIA60Hz

  • FACTORESPARACALCULODEREGULACION

    FP:0,9 UNIDADES:%/KVAMETRO(X10^4)

    CALIBRE3F2H208

    1F2H120

    3F4H3F3H480/277

    3F2H480

    1F2H277

    12 264,578 793,734 24,841 49,682 149,04610 164,724 494,172 15,466 30,932 92,7968 109,778 329,334 10,307 20,614 61,8426 70,762 212,286 6,644 13,288 39,8644 45,418 136,254 4,266 8,528 25,5842 29,796 89,388 2,797 5,594 16,7821/0 19,760 59,280 1,855 3,710 11,1302/0 16,176 48,528 1,519 3,038 9,1143/0 13,206 39,618 1,240 2,480 7,4404/0 11,026 33,078 1,035 2,070 6,210250 9,744 29,232 0,915 1,830 5,490300 8,532 25,596 0,811 1,622 4,866400 7,008 21,024 0,658 1,316 3,948500 6,064 18,192 0,569 1,138 3,414

    1'' 11/2'' 2'' 21/2'' 3'' 4''

    10 7 8 4 18 20 6 3 9 10 15 23 4 2 7 8 11 17 302 5 7 9 13 231 4 4 6 9 161/0 3 4 5 8 142/0 4 5 7 133/0 4 6 104/0 4 5 9250 4 7300 4 6350 5400 5500 4

    CALIBREDELCONDUCTOR

    DIAMETRODELTUBO

    CAPACIDADESDETUBERIANORMAENERGIAAE235

top related