crous ledcrous chemicals gmbh industrie allmend 30 ch-4629 fulenbach telefon: +41 (0)62 398 39 39...
Post on 19-Jan-2021
16 Views
Preview:
TRANSCRIPT
Crous Chemicals GmbH Industrie Allmend 30 CH-4629 Fulenbach
Telefon: +41 (0)62 398 39 39Fax: +41 (0)62 398 39 38Email: info@crous-chemicals.com
Crous LEDAuszug aus dem Hauptkatalog 2015
T8 LED Tube Train-Series
Beleuchtung für Schienenfahrzeuge
KATALOG 2015 - Auszug
Crous LED Co., Limited Flat/RM A 9/FSilvercorp International tower707-713 Nathan RoadMongkok - Hong Konginfo@led.cr
香港九龙旺角弥敦道707-713号银高国际大厦9楼A室
Crous LED AG Dorfstraße 38CH-6341 Baar
Telefon: +41 (0)62 398 39 39Fax: +41 (0)62 398 39 38Email: info@crous-chemicals.com
Crous LED PTY 55 Stella RoadMONTAGUE GARDENS 7441Western Cape, South AfricaTelefon: +27 81 44 90 760
Email: info@led.cr
Crous Chemicals GmbH Im Heetwinkel 6D-46514 Schermbeck
Telefon: +49 (0)28 53 95 63 800Fax: +49 (0)28 53 95 63 801Email: info@led.cr
Wir übernehmen keine Haftung für Druckfehler. Irrtümer vorbehalten, technische Änderungen und Verbesserungen sind möglich und behalten wir uns ebenfalls vor.Farben können drucktechnisch von den orginalen abweichen. Alle Produktabbildungen ähnlich. Produktabbildungen nicht maßstabsgetreu.
Crous Chemicals GmbH Industrie Allmend 30CH-4629 Fulenbach
Telefon: +41 (0)44 829 22 30Telefon: +41 (0)44 829 22 31Fax: +41 (0)44 829 22 32Email: info@led.cr
Photos: © 2009 - 2015 Lars Fehlandt © 2011 Crous Chemicals GmbH
03
Länge(mm)
Power (W)
LED Chip CCT(K)
verfügbare Betriebsspannungen CRI(Ra)
Abstrahlwinkel(Grad)
24 VDC 36 VDC 72 VDC 110 VDC 230 VAC
590 11 3020 3000K4000K5000K6500K
• • • • •>80 120°
1200 22 3020• • • • •
>80 120°
Parameter
Installation Dimensionen
Einsatzbereich Ta 25°C Elektrische Daten
Temperatur Luftfeuchtigkeit
Einsatz -20~+40°C Einsatz 10% - 80%
Lagerung -40~+85°C Lagerung 10% - 80%
Spannungsbereich Un 0.7 - 1.25
PF: >0.93 THD<20%
Energie Effizienz: >0.87
CROUS T8 LED “train” P-TypePatentierte, um 180° drehbare Endkappe für eine optimale Ausleuchtung.Aluminium PCB für eine bessere Wärmetransmission.Maximale Effizienz und minimale Blendung.Speziell für den Einsatz in Schienenfahrzeugen optimiert.
2
Crous LED
04
CROUS T8 LED “train” V-TypePatentierte, um 180° drehbare Endkappe für eine optimale AusleuchtungAluminium PCB für eine bessere WärmetransmissionMaximale Effizienz und minimale BlendungSpeziell für den Einsatz in Schienenfahrzeugen.V-Type mit mehr als 200° Ausleuchtung für bessere Ausleuchtung.
Länge(mm)
Power (W)
LED Chip CCT(K)
verfügbare Betriebsspannungen CRI(Ra)
Abstrahlwinkel(Grad)
24 VDC 36 VDC 72 VDC 110 VDC 230 VAC
590 11 3020 3000K4000K5000K6500K
• • • • •>80 >200°
1200 22 3020• • • • •
>80 >200°
Parameter
Installation Dimensionen
Einsatzbereich Ta 25°C Elektrische Daten
Temperatur Luftfeuchtigkeit
Einsatz -20~+40°C Einsatz 10% - 80%
Lagerung -40~+85°C Lagerung 10% - 80%
Spannungsbereich Un 0.7 - 1.25
PF: >0.93 THD<20%
Energie Effizienz: >0.87
2
05
CROUS T8 LED “train” two sidedPatentierte, um 180° drehbare Endkappe für eine optimale AusleuchtungAluminium PCB für eine bessere WärmetransmissionMaximale Effizienz und minimale BlendungSpeziell für den Einsatz in Schienenfahrzeugen.Optimierte Abstrahlung in zwei Richtungen.
Installation Dimensionen
2
Länge(mm)
Power (W)
LED Chip CCT(K)
verfügbare Betriebsspannungen CRI(Ra)
Abstrahlwinkel(Grad)
24 VDC 36 VDC 72 VDC 110 VDC 230 VAC
590 11 3020
3000K4000K5000K6500K
• • • • •>80 2 x 120°
895 15* 3020• • • • •
>80 2 x 120°
1200 22 3020• • • • •
>80 2 x 120°
Parameter
Einsatzbereich Ta 25°C Elektrische Daten
Temperatur Luftfeuchtigkeit
Einsatz -20~+40°C Einsatz 10% - 80%
Lagerung -40~+85°C Lagerung 10% - 80%
Spannungsbereich Un 0.7 - 1.25
PF: >0.93 THD<20%
Energie Effizienz: >0.87
*technische Änderungen vorbehalten.
Crous LED
06
Anschluss der CROUS T8 LED “train”
-+
-+
-+ Productlabel
Productlabel
+-
+-
07
Y
Z
Y
X
Y
X
Z
X
814
26
2
11
25
• 589mm • 895mm • 1200mm • 1500mm •
(alle Angaben in mm)
Crous LED
Bemaßung der CROUS T8 LED “train”
08
Instrument StatusScan Range: 380nm-780nm Interval: 5nm PMT HV: -510V
Main: 1 Id: 12 Ip: 22746
Reference: 3 REF: 20389 %: -0.593%
Instrument Manufacturer: VolnicTMPhoto-Electrical www.volnic.cn
Light Source Test Report
Model: Manufacturer:
Ambient TemperatureTa: 26.1Internal Temp. of Sphere: 25.8Humidity: 65%
Instrument:FMS-3000 Color Test SystemOperator:Date:2015-07-08
ElectricalPhotometricColor & Spectrum
Chromaticity Coordinate
x=0.3712 u=0.2207y=0.3725 v=0.3322
CCT 4231KPeak Wavelenth 433nmFWHM 25.1nmRed Ratio 0.192Blue Ratio 0.037Green Ratio 0.770CRI.(Ra) 84.4
( R1= 83 R2= 91 R3= 95 R4= 82 R5= 83 R6= 86 R7= 87 R8= 68 R9= 16 R10= 77 R11= 81 R12= 61 R13= 85 R14= 98 )
Luminous Flux 2280.8lm
Efficiency 98.7lm/WLight Power 7.0467w
Voltage 24.0V
Current 0.964APower 23.1W
380 480 580 680 780
0.5
1.0
SDCM: 4.1 SDCM
F4000(x=0.380 y=0.380)
Messdaten / Lichttechnik (Auszug) / Bsp. CROUS T8 LED “train” V-Type 1200mm 4000K
Wavelength Relative Spectral Energy Distribution Wavelength Relative Spectral Energy Distribution
380nm 0.0050
385nm 0.0033
390nm 0.0024
395nm 0.0019
400nm 0.0020
405nm 0.0028
410nm 0.0061
415nm 0.0137
420nm 0.0309
425nm 0.0597
430nm 0.1174
435nm 0.2054
440nm 0.3769
445nm 0.6300
450nm 0.9445
455nm 0.9793
460nm 0.7259
465nm 0.5680
470nm 0.4526
475nm 0.3608
480nm 0.3038
485nm 0.3059
490nm 0.3331
495nm 0.3743
500nm 0.4294
505nm 0.4801
510nm 0.5269
515nm 0.5611
520nm 0.5887
525nm 0.6116
530nm 0.6296
535nm 0.6460
540nm 0.6616
545nm 0.6832
550nm 0.7011
555nm 0.7212
560nm 0.7431
565nm 0.7636
570nm 0.7824
575nm 0.8003
580nm 0.8150
585nm 0.8261
590nm 0.8325
595nm 0.8340
600nm 0.8274
605nm 0.8147
610nm 0.7902
615nm 0.7629
620nm 0.7217
625nm 0.6840
630nm 0.6338
635nm 0.5901
640nm 0.5375
645nm 0.4942
650nm 0.4423
655nm 0.4012
660nm 0.3544
665nm 0.3161
670nm 0.2753
675nm 0.2438
680nm 0.2101
685nm 0.1852
690nm 0.1592
695nm 0.1393
700nm 0.1180
705nm 0.1031
710nm 0.0874
715nm 0.0758
720nm 0.0645
725nm 0.0561
730nm 0.0479
735nm 0.0416
740nm 0.0358
745nm 0.0314
750nm 0.0273
755nm 0.0240
760nm 0.0208
765nm 0.0190
770nm 0.0165
775nm 0.0151
780nm 0.0137
09
Crous LED
Messdaten / Lichttechnik (Auszug) / Bsp. CROUS T8 LED “train” V-Type 1200mm 4000K
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME: Coach T8 LED tube
DIM.: 1200*26mm
MFR.: Crous
TYPE:V F
SPEC.:24VDC 22W 4000K
SUR.:1.2*0.026
WEIGHT:
SERIAL No.:20150707-03
PROTECTION ANGLE:
Test:U:24.00V I:0.9425A P:22.62W PF:1.000 Lamp Flux:11.3018x204 lm
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,141.9deg
UNIT:cd
C30/210,131.5deg
UNIT:cd
C60/240,113.6deg
UNIT:cd
C90/270,107.6degAVERAGE BEAM ANGLE(50%):123.7 DEG
0
130
260
390
520
650
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)
3
4
5
6
7
8
9
10
11
0.0 4.5 9.0S(m)91.0
76.060.045.030.0
15.012.07.606.004.50
DATA OF LAMP PHOTOMETRIC DATA Eff: 101.93 lm/W
MODEL
NOMINAL POWER(W)
RATED VOLTAGE(V)
NOMINAL FLUX(lm)
LAMPS INSIDE
TEST VOLTAGE(V)
Imax(cd)
LOR(%)
TOTAL FLUX(lm)
CIE CLASS
up(%)
down(%)
S/MH(C0/180)
S/MH(C90/270)
UP,DN(C0-180)
UP,DN(C180-360)
CIBSE SHR NOM
CIBSE SHR MAX
Everlight3020
22
24
11.3018
204
24
611.1
100.0
2305.6
SEMI-D.
12.2
87.8
1.42
1.25
7.2,46.4
5.0,41.4
1.25
1.35
C Range: 0 - 360DEGC Interval: 30.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.274Temperature:25.3DEG Humidity:65.0%
Test Distance:7.100m [K=1.0000]Operators:Peng ShuangTest Date:2015-07-07 Remarks:
Checker: Peng Shuang Assessor: Xue Jinkui
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 11
ISOCANDELA DIAGRAM
NAME: Coach T8 LED tube
DIM.: 1200*26mm
MFR.: Crous
TYPE:V F
SPEC.:24VDC 22W 4000K
SUR.:1.2*0.026
WEIGHT:
SERIAL No.:20150707-03
PROTECTION ANGLE:
Test:U:24.00V I:0.9425A P:22.62W PF:1.000 Lamp Flux:11.3018x204 lm
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
HORIZONTAL(DEG)
VERT
ICAL
(DEG
)Imax:611.1(H10.0,V0.0) (At:C=0.0,Gamma=10.0)
UNIT: cd
5% 30.5510% 61.1115% 91.6620% 122.225% 152.830% 183.335% 213.940% 244.445% 275.050% 305.555% 336.160% 366.765% 397.270% 427.875% 458.380% 488.985% 519.490% 550.095% 580.5
C Range: 0 - 360DEGC Interval: 30.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.274Temperature:25.3DEG Humidity:65.0%
Test Distance:7.100m [K=1.0000]Operators:Peng ShuangTest Date:2015-07-07 Remarks:
Checker: Peng Shuang Assessor: Xue Jinkui
Crous T8 LED “train” Crous T8 LED “train”
10
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 11
AAI Figure
NAME: Coach T8 LED tube
DIM.: 1200*26mm
MFR.: Crous
TYPE:V F
SPEC.:24VDC 22W 4000K
SUR.:1.2*0.026
WEIGHT:
SERIAL No.:20150707-03
PROTECTION ANGLE:
Test:U:24.00V I:0.9425A P:22.62W PF:1.000 Lamp Flux:11.3018x204 lm
1m3.281ft
282.75cm9.277ft
194.5,604.8lx18.07,56.18fc
2m6.562ft
565.50cm18.55ft
48.62,151.2lx4.517,14.05fc
3m9.843ft
848.25cm27.83ft
21.61,67.19lx2.007,6.243fc
4m13.12ft
1131.00cm37.11ft
12.15,37.80lx1.129,3.511fc
5m16.4ft
1413.74cm46.38ft
7.779,24.19lx0.7227,2.247fc
Height Eavg,Emax DiameterAngle:109.45deg
Flux out:1246 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 30.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.274Temperature:25.3DEG Humidity:65.0%
Test Distance:7.100m [K=1.0000]Operators:Peng ShuangTest Date:2015-07-07 Remarks:
Checker: Peng Shuang Assessor: Xue Jinkui
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 11
ISOLUX DIAGRAM
NAME: Coach T8 LED tube
DIM.: 1200*26mm
MFR.: Crous
TYPE:V F
SPEC.:24VDC 22W 4000K
SUR.:1.2*0.026
WEIGHT:
SERIAL No.:20150707-03
PROTECTION ANGLE:
Test:U:24.00V I:0.9425A P:22.62W PF:1.000 Lamp Flux:11.3018x204 lm
131.2' 40.00m
105.0' 32.00m
32.00m
105.0'
78.7' 24.00m
52.5' 16.00m
16.00m
52.5'
26.2' 8.00m
0.0' 0.00m
0.00m
0.0'
26.2' 8.00m
52.5' 16.00m
16.00m
52.5'
78.7' 24.00m
105.0' 32.00m
32.00m
105.0'
131.2' 40.00m
MOUNTING HEIGHT: 33'(10.0m)
3% 0.1809lx 0.0168fc
5% 0.3015lx 0.02801fc
10% 0.6029lx 0.05601fc
30% 1.809lx 0.168fc
50% 3.015lx 0.2801fc
C Range: 0 - 360DEGC Interval: 30.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.274Temperature:25.3DEG Humidity:65.0%
Test Distance:7.100m [K=1.0000]Operators:Peng ShuangTest Date:2015-07-07 Remarks:
Checker: Peng Shuang Assessor: Xue Jinkui
Messdaten / Lichttechnik (Auszug) / Bsp. CROUS T8 LED “train” V-Type 1200mm 4000K
Crous T8 LED “train” Crous T8 LED “train”
11
Crous LED
Zertifikate
LVD Richtlinie 2014/35/
EUEN 50155/2007
• für 72VDC
LVD Richtlinie 2014/35/EU
EN 50155/2007
• für 110VDC
LVD Richtlinie 2014/35/
EUEN 50155/2007
• für 230VAC
EMC Richtlinie 2014/30/EU
EN 50121-3-2: 2015
IEC 62236-3-2: 2008
EN 55016-1-2: 2014
EN 50155: 2007
• für 110VDC
EMC Richtlinie 2014/30/EU
EN 50121-3-2: 2015
IEC 62236-3-2: 2008
EN 55016-1-2: 2014
EN 50155: 2007
• für 230VAC
EMC Richtlinie 2014/30/EU
EN 50121-3-2: 2015
IEC 62236-3-2: 2008
EN 55016-1-2: 2014
EN 50155: 2007
• für 24VDC
LVD Richtlinie 2014/35/EU
EN 50155/2007
• für 24VDC
EMC Richtlinie 2014/30/EU
EN 50121-3-2: 2015
IEC 62236-3-2: 2008
EN 55016-1-2: 2014
EN 50155: 2007
• für 72VDC
12
Die in diesem Bericht enthaltenen Ergebnisse beziehen sich ausschließlich auf den zur Prüfung vorgestellten Gegenstand. Eine auszugsweise Vervielfältigung ist ohne schriftliche Genehmigung des Prüflaboratoriums nicht gestattet. Ber2012-0101-VU_Crous_Chemicals_Heuberger(Pdf-Vorlage)
Prüfbericht
Nr.: 2012-0101-VU
Datum der Prüfung: März 2012
Prüfer: Dipl.-Ing. Wenderoth, ,lhörP .gnI-.lpiD
reuahnedafP rekinhceT
Anzahl der Seiten: 20
Antragsteller: Crous LED,ein Unternehmensbereich der Crous Chemicals GmbH Industrie Allmend 30 CH-4629 Fulenbach
Hersteller: Crous LED
Prüflinge: 2x LED Tube / Sunstrip
Model : CLED 0590mm/24V/VPS Model : CLED 1200mm/24V/VPS
Baugleich gemäß Matrix auf den Seiten 19-20
Anlieferung: 08.03.2012
Prüfverfahren / Grundlagen: Vibrationsprüfung, rauschförmig:
Basisnorm: DIN EN 60068-2-64 Prüfvorschrift: DIN EN 61373 / 1999 Mechanischer Schock:Basisnorm: DIN EN 60068-2-27 Prüfvorschrift: DIN EN 61373 / 1999
Berichtsdatum: 20.03.2012
Prüflinge:
Abbildung 1: Prüflinge
Abteilung Umweltsimulation
AKUVIB Engineering and Testing GmbH Sinterstraße 8 44795 Bochum
Telefon Zentrale: +49 (0)234 587-6000 Telefax: +49 (0)234 587-6005 Internet: www.akuvib.de
Geschäftsführung: Dr. Jörg Hansen
Handelsregister:Amtsgericht Bochum HRB 8958
Bankverbindung: Volksbank Bochum BLZ 430 601 29 Konto 123 357 801
Sparkasse Herne BLZ 432 500 30 Konto 363 50
Ust.-Id.: DE814089782
BrandtestDIN EN 54837/2007DIN EN 5510-2/2009
VibrationstestDIN EN 60068-2-64
DIN EN 61373 / 1999DIN EN 60068-2-27
DIN EN 61373 / 1999
Rauchgastoxizität
DIN EN ISO 5659-2:2007DIN 5510-2:2009 D2DIN5510-2:2009
Prüfung nach
DIN 55350-18-4.3.4EN 50155-12.2.3EN 50155-12.2.4EN 50155-12.2.5
EN 50155-12.2.9
Emissions TestEN 50121-3-2:2006
IEC 62236-3-2:2008-12EN 55016-1-2
EN 61000
Zertifikate
EMV Rhein-Neckar GmbHTest Report No.: 4613-302 dated 22.07.2014 Page 3 / 25
© 2014 EMV Rhein-Neckar GmbH, Dornierstr. 5a, 68519 Viernheim
Summary
This test report contains the results of the - emission tests
on the - Coach T8 LED Tube P/590/50/F; - CLED T8 Train Tube V/590/40/F, - CLED T8 Train Tube V/1200/40/F and - Coach T8 LED Tube V/1200/50/F of the Crous LED Co. Limited, Mongkok Hong Kong, China.
The emission requirements according to the regulation - Regelung Nr. EMV 06, Technische Regeln zur Elektromagnetischen Verträglichkeit,
Nachweis der Funkverträglichkeit von Schienenfahrzeugen mit Bahnfunkdiensten, Rev. -Nr. 1.0 dated 29.07.2014
are fulfilled.
The results in this report relate exclusively to the sample(s) tested.
Regelung Nr. EMV 06
Technische Regeln zur Elektromagnetischen Verträglichkeit.
Nachweis der Funkverträglichkeit von Schienenfahrzeugen mit Bahnfunkdienst.
13
Reiner Reck Verkauf Deutschland
+49 170 33 38 710
reiner.reck@crous-chemicals.com
Norbert Helm Verkauf Schweiz
+41 79 658 40 41
norbert.helm@led.cr
Marcel Ruchti Verkauf Schweiz
+41 79 789 66 72
marcel.ruchti@led.cr
Thomas Schönberger Verkauf Österreich
+43 664 281 58 93
austria@led.cr
Wolfgang Gauges Verkauf Österreich
+43 664 450 90 69
austria@led.cr
Peter A. Müller Sales International
+41 79 758 46 04
peter.mueller@led.cr
Julian Crous CEO Sales International
+49 151 12 20 80 52
+41 79 31 03 509
Camillia Crous Sales International
+41 79 789 73 66
camillia.crous@led.cr
Bettina Heuberger Sales International
+41 78 74 66 488
bettina.heuberger@led.cr
julian.crous@led.cr
Byron Walsh Sales South Africa
+27 81 44 90 760
byron@led.cr
Lars Fehlandt Technischer Support / technical support
+49 171 93 19 501
L.F@crous-chemicals.com
Marc Goelden Technischer Support / technical support
+49 151 12 20 80 54
M.G@crous-chemicals.com
Ansprechpartner R&D.
lars.fehlandt goeldenmarc
Ansprechpartner Sales.Crous LED
1414
Schutzart nach DIN 40 050 Teil 9 und DIN EN 60529• Geschützt gegen feste Fremdkörper mit Durchmesser ab 12,5 mm.
Schutzart nach DIN 40 050 Teil 9 und DIN EN 60529• Geschützt gegen feste Fremdkörper mit Durchmesser ab 1,0 mm.
Schutzart nach DIN 40 050 Teil 9 und DIN EN 60529• Staubdicht.• Schutz gegen Strahlwasser (Düse) aus beliebigem Winkel.
Schutzart nach DIN 40 050 Teil 9 und DIN EN 60529• Staubdicht.• Schutz gegen starkes Strahlwasser.
Schutzart nach DIN 40 050 Teil 9 und DIN EN 60529• Staubdicht.• Schutz gegen zeitweiliges Untertauchen.
Schutzart nach DIN 40 050 Teil 9 und DIN EN 60529• Staubdicht.• Schutz gegen dauerndes Untertauchen.
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)Keine Schlagfestigkeit
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)0.14 Joule
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)0.20 Joule
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)0.35 Joule
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)0.5 Joule
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)0.7 Joule
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)1.0 Joule
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)2.0 Joule
Stoßfestigkeitsgrad nach IEC 62262(entspricht EN 62262, früher EN 50102)5.0 Joule
Steuerung über Funk via 2.4Ghz
• Remote Control
EU Richtline zur Beschänkung bestimmter gefärlicher Stoffe in Elekro- und Elektronik Geräte.
Explosionsschutz gemäß ATEX.
Symbolverzeichnis
15
DALI
Die CE-Kennzeichnung ist das Zeichen für die Entsprechung der auferlegten Anforderungen der Europäischen Union.
Produkte sind bei der DB gelistet.
Dimmung via 0-10VDC Schnittstelle.(auch 1-10VDC möglich)
Steuerung via DALI.(Digital Addressable Lighting Interface)
Dimmung via TRIAC bzw. phase-cut.
Dieses Produkt wurde nach den für die BahnspezifiischenNormen für elektromagnetischer Verträglichkeit geprüft.Inkl. Nachweis der Funkverträglichkeit.
Dieses Symbol zeigt die Produkt-Garantie in Jahren.
Nur innerhalb von Gebäuden zu verwenden.
Produkt ist nicht dimmbar.
Alle elektrisch leitfähigen Gehäuseteile des Betriebsmittels sind mit dem Schutzleitersystem der festen Elektroinstallation verbunden, welches sich auf Erdpotential befindet.
Betriebsmittel mit Schutzklasse II haben eine verstärkte oder doppelte Isolierung zwischen Netzstromkreis und Ausgangss-pannung beziehungsweise Metallgehäuse.
Betriebsmittel der SK III arbeiten mit Schutzkleinspannung und benötigen bei Netzbetrieb eine verstärkte oder doppelte Iso-lierung zwischen Netzstromkreisen und der Ausgangsspannung.
Produkte sind durch den TÜV zertifiziert.
Produkte sind durch den VDE zertifiziert.
Defekte Elektrogeräte dürfen nicht einfach mit dem Hausmüll entsorgt werden.• WEEE-Richtline Waste of Electrical and Electronic Equipment
Zeitpunkt nach dem ein Ausfall der einzelnen Lampe oder 50% der Lampen einer Anlage zu erwarten sind. (L50)
15
Für den Einsatz unter rauhen Bedingungen
Color Rendering Index / Farbwiedergabeindex / RA-Wert.
• Bei diesem Produkt ist ein CRI optional von >93 möglich.
Crous LED