secuencia electroneumática y plc

Upload: erick-jesus-rodriguez-davila

Post on 04-Mar-2016

98 views

Category:

Documents


3 download

DESCRIPTION

plc

TRANSCRIPT

Secuencia Electroneumtica: A+B+A-B-Incluye contador y temporizador

Programa de PLC: A+B+A-B-Incluye contador y temporizador

""A+B+A-B- (INCLUYE CONTADOR Y TEMPORIZADOR)

STEP 1 IF I0.0 'PULSADOR 1 THEN LOAD V0 TO CW0STEP 2 IF I0.2 'A0 THEN SET O0.0 'EXT_CIL1 RESET O0.1 'RET_CIL1STEP 3 IF I0.3 'A1 THEN SET O0.2 'EXT_CIL2 RESET O0.3 'RET_CIL2 SET T1 'TEMP 1 WITH 5sSTEP 4 IF I0.5 'B1 AND N T1 'TEMP 1 THEN SET O0.1 'RET_CIL1 RESET O0.0 'EXT_CIL1STEP 5 IF I0.2 'A0 THEN SET O0.3 'RET_CIL2 RESET O0.2 'EXT_CIL2STEP 6 IF N I0.5 'B1 THEN INC C0 'CONT 0STEP 7 IF CW0 = V5 THEN JMP TO 1 OTHRW JMP TO 2

""A+B+A- B-(INCLUYE CONTADOR Y TEMPORIZADOR)

STEP 1 IF I0.0 'PULSADOR 1 THEN LOAD V0 TO CW0STEP 2 IF I0.2 'A0 THEN SET O0.0 'EXT_CIL1 RESET O0.1 'RET_CIL1STEP 3 IF I0.3 'A1 THEN SET O0.2 'EXT_CIL2 RESET O0.3 'RET_CIL2 SET T1 'TEMP 1 WITH 5sSTEP 4 IF I0.5 'B1 AND N T1 'TEMP 1 THEN SET O0.1 'RET_CIL1 RESET O0.0 'EXT_CIL1 SET O0.3 'RET_CIL2 RESET O0.2 'EXT_CIL2STEP 6 IF N I0.5 'B1 THEN INC C0 'CONT 0STEP 7 IF CW0 = V5 THEN JMP TO 1 OTHRW JMP TO 2