ok muro de contencion tipo4
DESCRIPTION
1231TRANSCRIPT
ANCHO SOBRECARGA
MURO 0.400 0.500 T/M2
T
DATOS (MTS)
SISMO
Bz= 2.45 mts 0.50
T = 0.40 mts DENSIDAD ALTURA
hz= 0.60 mts 1.88 Tn/m3 P2 Hp 4.20
Hp= 4.20 mts Dp 4.20 Fp ANGULO FRICCION
E = 0.35 mts 33 º
G = 0.00 mts
Dp= 4.20 mts P3 P5
Fp= 4.20 6
M = 1.20 mts M E G N
N = 0.50 mts Hd 1.200 P1 hz 0.60
Hd= 1.20 mts
B
BASE 2.450
Peso especifico del concreto (w)= 2.40 T/m3
Peso especifico suelo (&)= 1.88 T/m3
Angulo de Friccion (ø)= 32.74 Grados
Presion admisible de terreno (q)= 1.42 Kg/cm2
Coeficiente Friccion (u) 0.60 0.52
S/C 0.50 T/m2
Elemento Peso (Ton) Brazo (m) Mr = P*X h s/c 0.266 mts
1 3.53 1.23 4.32
2 4.03 1.75 7.06 Ka 0.298
3 1.76 1.43 2.53
4 0.00 1.95 0.00 Pa 2.688
5 3.95 2.20 8.68
S/C 0.25 2.20 0.55 Ps/c 0.149
Total 13.52 23.14
Ea 6.45 1.60 10.32 u 0.600
S/C 0.72 2.40 1.72
Total 7.17 12.04
** Si consideramos el empuje pasivo Ep para aumentar la fuerza estabilizadora construyendo un
diente de Cº
Ep = 4.54 Tn/m
FS = M estabiliz = 1.92 >1.5 CONFORME
VERIFICACION DE ESTABILIDAD
VERIFICACION DE MUROS DE CONTENCIÓN TIPO 04 H=4.80M
CHEQUEO AL VOLTEO
VERIFICACION DE MUROS DE CONTENCIÓN TIPO 04 H=4.80M
M volteo
FS = u*Fv +Ep 1.77 >1.50 CONFORME
Fh
X = ( Mr - Ma ) 0.82
P
e = B/2 - X 0.40
B/6 > e = 0.41 >e CONFORME
q1 = 10.98 tn/m2 CONFORME
q2 = 0.06 tn/m2 CONFORME
q<0 existe traccion
0.06
10.98
CHEQUEO AL DESLIZAMIENTO
VERIFICACIONES DE PRESIONES SOBRE EL TERRENO