espectro de diseÑo tanque imhoff finalx
TRANSCRIPT
DATOSZ= FACTOR DE USO DE LA ZONA Z = 0.3
U = FACTOR DE USO DE IMPORTANCIA U = 1.3
S = FACTOR DEL SUELO S = 1.4
C= COEFICIENTE SISMICO Rd = 6
Rd = FACTOR DE DUCTILIDAD Ts = 0.9
T= PERIODO DE VIBRACION FUNDAMENTAL DE LA ESTRUCTURA
DATOS
0.00 2.500 2.232 Hn= 7.90.10 2.500 2.232 Ct= 350.20 2.500 2.2320.30 2.500 2.232 ANALISIS ESTATICO0.40 2.500 2.232 T= 0.2260.50 2.500 2.232 C= 2.5000.60 2.500 2.232 Sa= 2.2320.70 2.500 2.2320.80 2.500 2.2320.90 2.500 2.2321.00 2.250 2.0091.10 2.045 1.826 Ct = 35 PORTICOS
1.20 1.875 1.674 Ct = 45 PORTICOS Y CAJAS
1.30 1.731 1.545 Ct = 60 PORTICOS CON PLACAS Y MANPOSTERIA
1.40 1.607 1.4351.50 1.500 1.339 Hn = ALTURA DE LA EDIFICACION
1.60 1.406 1.255
1.70 1.324 1.1821.80 1.250 1.1161.90 1.184 1.0572.00 1.125 1.004
T C Sa
ANALISIS DINAMICO
MEM. DE CALCULO - CALCULO DE LA ACELERACION ESPECTRAL
Ct
HnT =
=TTs
C 5.2Rd
gSCUZSa
....=
MUNICIPALIDAD
DISTRITAL DE
SIMON BOLIVAR
PROYECTO: MEJORAMIENTO Y AMPLIACION DE LOS SERVICIOS DE AGUA Y DESAGUE
EN EL CENTRO POBLADO DE SACRAFAMILIA, DISTRITO DE SIMON BOLIVAR - PASCO -
PASCO
LOCALIDAD : SACRAFAMILIA
DISTRITO : SIMON BOLIVAR
PROVINCIA : PASCO
REGION : PASCO FECHA : JUNIO 2011
MEM. DE CALCULO - CALCULO DE LA ACELERACION ESPECTRAL
MUNICIPALIDAD
DISTRITAL DE
SIMON BOLIVAR
PROYECTO: MEJORAMIENTO Y AMPLIACION DE LOS SERVICIOS DE AGUA Y DESAGUE
EN EL CENTRO POBLADO DE SACRAFAMILIA, DISTRITO DE SIMON BOLIVAR - PASCO -
PASCO
LOCALIDAD : SACRAFAMILIA
DISTRITO : SIMON BOLIVAR
PROVINCIA : PASCO
REGION : PASCO FECHA : JUNIO 2011
0.000
0.500
1.000
1.500
2.000
2.500
0.00 0.50 1.00 1.50 2.00 2.50
Sa
T
ESPECTRO E-030