ejemplos - flexion - parte 2

Upload: wermer-melgar-gutierrez

Post on 04-Apr-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 Ejemplos - Flexion - Parte 2

    1/3

    F-20

    Example F.3a W-Shape Flexural Member with NoncompactFlanges in Strong-Axis Bending

    Given:

    Select an ASTM A992 W-shape beam with a simple span of 40 feet. The nominal loads are a

    uniform dead load of 0.05 kip/ft and two equal 18 kip concentrated live loads acting at the

    third points of the beam. The beam is continuously braced. Also calculate the deflection.

    Note: A beam with noncompact flanges will be selected to demonstrate that the tabulated

    values of the Steel Construction Manualaccount for flange compactness.

    Solution:

    Material Properties:

    ASTM A992 Fy = 50 ksi Fu = 65 ksi

    Calculate the required flexural strength at midspan

    LRFD ASD

    wu = 1.2(0.0500 kip/ft) = 0.0600 kip/ftPu = 1.6(18.0 kips) = 28.8 kips

    Mu =

    20.0600 kip/ft 40.0 ft

    8

    + 40.0 ft

    28.8kips3

    = 396 kip-ft

    wa = 0.0500 kip/ftPa = 18.0 kips

    Ma =

    20.0500 kip/ft 40.0 ft

    8

    + 40.0 ft

    18.0kips3

    = 250 kip-ft

    Select the lightest section with the required strength from the bold entries in Manual Table 3-2

    SelectW21u48.

    This beam has a noncompact compression flange atFy = 50 ksi as indicated by footnote f in

    Manual Table 3-2. This is also footnoted in Manual Table 1-1.

    Manual

    Table 3-2

    ManualTable 1-1

  • 7/29/2019 Ejemplos - Flexion - Parte 2

    2/3

    F-21

    Check the available strength

    LRFD ASD

    IbMn = IbMpx = 398 kip-ft > 396 kip-ft o.k. : :pxn

    b b

    MM= 265 kip-ft > 250 kip-ft o.k.

    Manual

    Table 3-2

    Note: the value Mpx in Table 3-2 include strength reductions due the noncompact nature of theshape

    Calculate deflection

    Ix = 959 in.4

    'max =4

    5

    384

    wl

    EI+

    3

    28

    Pl

    EI

    =

    4 3

    4

    5 0.0500 kip/ft 40.0 ft 12 in./ft

    384 29,000 ksi 959 in.+

    3 3

    4

    18.0 kips 40.0 ft 12 in./ft

    28 29,000ksi 959in

    = 2.66 in.

    This deflection can be compared with the appropriate deflection limit for the application.Deflection will often be more critical than strength in beam design.

    Manual

    Table 1-1

    Manual

    Table 3-23Diagrams 1

    and 9

  • 7/29/2019 Ejemplos - Flexion - Parte 2

    3/3

    F-22

    Example F.3b W-Shape Flexural Member with NoncompactFlanges in Strong-Axis Bending

    Given:

    Verify the results from Example F.3a by calculation using the provisions of the Specification.

    Solution:

    Material Properties:

    ASTM A992 Fy = 50 ksi Fu = 65 ksi

    Geometric Properties:

    W21u48 Sx = 93.0 in.3 Zx = 107 in.3

    Check flange slenderness

    O =2

    f

    f

    b

    t= 9.47

    The limiting width-thickness ratios for the compression flange are:

    Opf= 0.38y

    E

    F=

    29,000 ksi0.38

    50 ksi= 9.15

    Orf= 1.0y

    E

    F=

    29,000 ksi1.0

    50 ksi= 24.1

    Orf > O > Opf; therefore, the compression flange is noncompact. This could also be determinedfrom the footnote f in Manual Table 1-1.

    Calculate the nominal flexural strength, Mn

    Since the beam is continuously braced, and therefore not subject to lateral-torsional buckling,the available strength is governed by Section F3

    Mp =FyZx = 50 ksi(107 in.3) = 5350 kip-in. or 446 kip-ft.

    Mn = pf

    0.7pf

    p p y x

    rf

    M M F S O O

    O O

    Mn = 39.47 9.15

    5350kip-in. 5350kip-in 0.7 50ksi 93.0in.24.1 9.15

    = 5310 kip-in. or 442 kip-ft.

    ManualTable 2-3

    ManualTable 1-1

    Manual

    Table 1-1

    Table B4.1

    Case 1

    Eqn. F3-1

    Calculate the available flexural strength

    LRFD ASD

    Ib = 0.90IbMn = 0.90(442 kip-ft)

    = 398 kip-ft > 396 kip-ft o.k.

    :b = 1.67Mn:b = 442 kip-ft / 1.67

    = 265 kip-ft > 250 kip-ft o.k.

    Section F1

    Note that these available strength values are identical to the tabulated values in Manual Table3-2, which account for the non-compact flange.