Download - Class 3€¦ · Title: Microsoft PowerPoint - Class 3 Author: lan Created Date: 2/21/2014 7:44:05 PM
2/21/2014
1
�
Walls above ground
Application
1. Masonry 1. 11m
2. no support concrete floor construction
2. ICF1. Maxim floor to floor height 3m
2. Maxim 2 storeys,
3. Dwell only
4. S(0.2) ≤0.4
3. Wood frame (structure application)
4. Steel stud (No load barring )
2/21/2014
2
1. Block (table 9.20.2.7)
2. Mortar
1. Cement
2. Lime
3. Water
4. Aggregate
3. Block joints
4. Lintel
1. Steel lintel for masonry wall (table 9.20.5.2.A)
2. Steel lintel for masonry veneer(table 9.20.5.2.B)
3. Beam for masonry veneer (table 9.20.5.2.C)
Note: L steel: 150mm bearing, Beam: welded to columns
CementCementCementCement 7day (7day (7day (7day (MPaMPaMPaMPa)))) 28day (28day (28day (28day (MPaMPaMPaMPa))))
Type N 3.4 9.0
Type S 6.2 14.5
Type M 12.4 20
1. Thickness and height
1. Exterior
1. 140mm: one floor, 2.8m, 4.6m
2. 190mm: other floors
2. Interior (9.20.6.3)
2. Cavity wall
1. 90mm or 75mm units?
2. Cavity 50-150mm
3. Min. width 230mm for the top 7.6m and 330mm for the rest.
4. If 75mm units are used, max. height is 6m
3. Masonry veneer
1. Min. 70mm units
2. Min. 90mm units
3. Tying (table 9.20.9.5 )
2/21/2014
3
1. Single Wythe: Offset or 3.76m steel bar located 460mm with 150mm overlap
2. Multiple Wythe: cross interlock (9.20.9.3) or bonding tie
Normal wall Normal wall Normal wall Normal wall
460mm460mm460mm460mm
Cavity wallCavity wallCavity wallCavity wall
Within 300 mm Within 300 mm Within 300 mm Within 300 mm
around opening around opening around opening around opening
with 900 interval with 900 interval with 900 interval with 900 interval
9.20.7.29.20.7.29.20.7.29.20.7.2
2/21/2014
4
Less than 90mmLess than 90mmLess than 90mmLess than 90mm
2/21/2014
5
Note:
• min. wall thickness: 140mm
• Bar placed in the middle third of
the wall section
2/21/2014
6
1. Foundation wall shall use mortar of:
a) Type S
b) Type N
c) Type S or N
d) Not permitted
2. What’s the mortar joints thickness requirements?
3. Clear span is 2.0m with 7000 N/m floor load. 203mm
brick wall. What is the interior angle size and exterior size?
4. If the clear span is 5m, please design the lintel to support
the 90mm masonry veneer.
5. A interior load bearing wall has been lateral supported by
610mm O.C. joist. what’s the min. thick of the wall shall be?
2/21/2014
7
6. Which one is incorrect veneer tie spacing?
a) 400x800
b) 500x600
c) 500x500
d) 600x400
7. If a masonry wall has a opening, rod tie shall be placed
around the opening with in how many mm?
a) 300mm
b) 450mm
c) 600mm
d) 900mm
8. 1.8m wide window in 140mm ICF load bearing wall of a
bungalow building. Please design the lintel.
1. Stud sizing
1. Studs must be continues
2. One storey studs: table 9.23.10.1:
3. Multiple storey studs -table A-30 to A-33
2. Wall plate
1. Top
2. Bottom
3. Anchorage: dia. 12.7mm, 2.4m O.C, 100mm deep
3. Bracing and lateral support (9.23.10.2)
4. Wood frame, dia. 12.7mm, 2.4m O.C, 100mm deep
5. Notching and drilling
1. Studs 2/3, 40mm
2. Top plate 50mm
2/21/2014
8
1. Beside opening (9.23.10.6)
2. Over opining
1. Non loadbearing (38mm on around, double frame on
fire rated door)
2. Loadbearing (table A-12 to A-16)
1. Wall stud exceed 33x64
2. Wall stud is 38x64
3. Wall sheathing
1. When ?
2. Table 9.23.16.2.A or 9.23.16.2.B
3. 2mm gap is required between panels
4. Fastening requirement (table 9.23.3.5)
2/21/2014
9
1. No loadbearing
2. Interior (table 9.24.2.1)
3. Exterior (table 9.24.2.5)
4. Runners (fasten 50mm, 610mm, or 305mm)
5. Fire rated wall, 12mm expansion space
6. Openings
1. Double,
2. Triple if 2.4m wide in exterior
3. Fire damper opening (double, 300 long, 900 angle bend)
1. Determine the minimum stud size and spacing for studs
located in an exterior wall supporting a roof and one floor.
Assuming there is a high ceiling and that the unsupported
height of the studs is 3.4m.
1. Minimum stud size:
2. Maximum spacing:
2. Interior wood stud wall supporting and attic (not accessible
by a stairway) and tow floors.
1. Minimum stud size:
2. Maximum spacing:
3. When the plywood has been used to do the bracing job for
exterior wall. What is the min, thinness of the plywood shall
be?
2/21/2014
10
4. What are the minimum permissible sizes and the
maximum spacing of studs for an interior wall on third
floor?
5. A 38x140 loadbearing wall stud will be drilled to install a
drainage pipe. What is the maxim diameter of the hole can
be?
6. A house is located in downtown Toronto. A window width is
2.0m located on third floor of exterior wall. The wall
support roof and ceiling only with tributary with width of
4.5m. Please select Douglass Fir-larchNo.1 Grade lintel
size to protect the window. Can I use 2-38x140? What if
the house will be built in North York? What if the exterior
wall stud is 38x64?