ACTIVA-SIts the S inside that counts
Offer your lab Simplicity in a high
performance Spectrometer.
Sotware or all
Supplies
ACTIVA S
-
7/28/2019 Activa s Horiba
2/8
U
ltima
2Simply competitive
potential use o all ICP lines, and a Superior Semi-
quantitative analysis oers a precise identication o
the Samples.
Quality
The combination o HORIBA Scientifc high quality
optics with the advanced eatures o the CCD detector
is optimized to make the dierence. The ultra-low
noise and excellent practical dynamic range o
the CCD, associated to the constant resolution,
aberration ree, high luminosity holographic gratings
o the optical System, enable the instrument to t the
needs o Simplicity, Stability and Quality.
The high perormance CCD Sensor designed or
Scientic Spectroscopy provides excellent analytical
capabilities, obtained with minimal operator
optimisation. The powerul ACTIVAnalyst Sotware
enhances the unique capabilities o the instrumental
conguration.
ACTIVA-S is a CCD-based ICP-AES instrument based
upon A Platorm or the Future, maintaining the
Strengths o HORIBA Scientic Spectrometers while
incorporating advanced CCD (Charge Coupled Device)
technology to improve quality and fexibility.
ACTIVA-S is the perect Solution to rst-time operators
and or routine analysis with dened applications.
Simplicity
Both Spectrometer and Detector o ACTIVA-S oer
the ease-o-use that every analyst wishes. Plug-&-
Play operations and automatic optimisations help the
user to operate the instrument at its best and achieve
excellent analytical results.
Flexibility
The Total Plasma View, rom Superior vertical torch
based radial observation, combined with a light-rich,
high perormance optical System, allows the analyst to
run all types o Samples. The ull wavelength coverage,
rom 160 to 800 nm, emphasizes this fexibility: a
unique and proprietary ICP-based Spectral database
(rom S3-base: Single-element Spectra, Spectroscopic
data) leads to optimum Selectivity with
ACTIVA-S CCD-based ICP Atomic Emission SpectrometerCombines Simplicity with a high performance CCD Detector
2
AC
TIVA
S
-
7/28/2019 Activa s Horiba
3/8
Spectrometer of high quality
The Dual back-to-back gratings (4343 / 2400 g/mm)
oer constant Spectral resolution and ull fexibility in
line Selection. The optical resolution is better than 12
pm in the 160-430 nm range and less than 22 pm in
the 430-800 nm range.
High technology electronics with Rapid ChipTM
components leads to ast data transer and
processing.
The ultra low noise CCD Solid State detector
oers high productivity analysis o multiple elements
at multiple wavelengths including Simultaneous
background correction within a spectral window.
The rst-time user rapidly becomes condent in the
use o the instrument: optimisation operations oranalytical corrections are minimised and the plasma
conguration is ready or all applications.
Spacious Sample introduction area and convenient
corrosion resistant old-down Sample tray enable
the user to run any type o Samples with dedicated
Sample introduction Systems.
Quick release and quick mount torch design
in a large and user-riendly compartment, with no
adjustmentrequired, acilitates multi-user operation
and provides excellent reproducibility.
The Vertical Torch with Superior Total Plasma View
provides optimum Sensitivity, with reduced matrix
eects, or both aqueous and organic matrices. The
Sheath gas device, with a large 3 mm i.d. injector tube,
gives unique high dissolved Solids capability (up to
30% NaCl), with excellent long-term Stability, and
minimises memory eects.
Smart Hood provides Sae, convenient extraction
with reduced installation costs.
Reliable high eciency 40.68 MHz Solid State
generator enhances the ability to handle a wide variety
o applications and improves the limits o detection.
Warm-up time is also reduced (usually less than 15
minutes).
Excellence in Spectrometer configuration with attention to Simplicity,flexibility and quality
3
-
7/28/2019 Activa s Horiba
4/8
productivity analysis o multiple elements at multiple
wavelengths including background correction within a
Spectral window. The addition o adjacent Spectral
windows allows the System to cover the entire
Spectrum, or ast Semi-quantitative analysis with
multiple wavelengths.
ACTIVA-S is equipped with an Open Electrode CCD
(Charge Coupled Device) detector with an image area
o 26.6 x 6.7 mm. This detector is perectly Suited
to the Total Plasma View confguration by efciently
collecting all the useul inormation emitted by the
plasma. Simultaneous measurement provides high
capability then provide a practical dynamic range
(Signal beore saturation-to-readout noise ratio) o 107,
with a linear response range o 5 decades minimum,
or each line.
Analysis o trace and major elements can be easily
perormed with one measurement, without requiring
dilution.
A powerul pre-Shot algorithm automatically optimizes
exposure time and column binning, which takes
advantage o the ull benet o the maximum available
dynamic range. Binning o the 256 pixel-high column
results in a decrease in read-out time with no addition
o readout noise and an increase in the linear dynamic
range. The combination o ultra low noise and binning
Sensor for Spectroscopy
Unique CCD adapted to HORIBA Scientific quality optics
4
AC
TIVA
S
-
7/28/2019 Activa s Horiba
5/8
ACTIVAnalyst Sotware provides a data audit
trail or user and instrument operation, and an online
lab book to record daily actions perormed. Multi-level
Security permits user access levels or viewing and
editing.
The wavelength library is based on the unique and
proprietary S3-base developed by HORIBA Scientic,
eaturing not only actual wavelengths derived rom an
ICP Spectrometer, but also their Spectroscopic data
such as limit o detection, line width, etc.
Productivity is enhanced by automatic user
programmable Start up and Shutdown, minimising
argon usage.
Within a method, the user gets assistancein optimisation o line Selection and acquisition
parameters.
Productivity is urther enhanced with automated
analysis using a multi-method Sequence or Samples
o various matrices requiring dierent methods.
Barcode identication is available or Samples loaded
in a Sequence. Automatic unattended operation is
possible using the auto-Sampler with programmable
re-calibrations and QC checks with user dened
actions.
The Simultaneous measurement provides the
ability to visualise the Spectra o lines and their vicinityduring analysis, or ast conrmation o element
presence or visual identication o unexpected
Spectral intererences.
Automatic Superior Semi-quantitative analysis
o all elements is perormed rom ull Spectrum
acquisition (IMAGE) and with the Total View mode or
concentration calculation, data reporting and data re-
processing.
Urgent Samples can be inserted in an on-going
Sequence, using either the current method or any
other method.
When required, results can be optimised, using
various analytical correction methods. Results
reprocessing is
possible ater calibration or parameter changes.
The user benets o network ready results and
reporting with fexible export to a dened location orto a LIMS System.
Diagnostics data reporting allows the analyst to
control the perormance o the instrument.
SPC (Statistical Process Control) is included
or X, R, SD and histogram charts o user-Selected
Solutions.
Audit Trail Analyst or 21CFR Part 11 compliance
with a powerul SQL Server database oers data
Security with electronic Signatures and multi-level
authorisation logon, and an error log le.
TimeScan gives the possibility to have real-timeoutput o instrument Signal or troubleshooting, or or
transient Signal acquisition (data available or export
as a TXT le).
Software for allPowerful ACTIVAnalyst Software extends instrument capability and fullyutilizes the unique capabilities of Solid State detection
5
-
7/28/2019 Activa s Horiba
6/8
Supplies
Samples introduction systems
Other accessories
6
Sample Type / Item Nebuliser Spray Chambe
Standard
kit P/N: 24 031 500
Concentric, glass
P/N: 47 929 058
50 psi argon gas, 1 mL/min
sample uptake
Cyclone, glass
P/N: 47 929 056
High TDS / Mineral Salt
kit P/N:
24 072 160 (concentric / cyclo)
24 031 510 (parallel / cyclo)
24 031 570 (parallel / Scott)
Concentric, glass
P/N: 24 072 150
30 psi argon gas, 2 mL/min
sample uptake
Parallel fow, PEEK/Tefon
P/N: 47 929 024
50 psi argon gas, 1 mL/min
sample uptake
Cyclone, glass
P/N: 47 929 056
I sensitivity is the main criteria
Scott, glass
P/N: 31 031 491
I stability is the main criteria
Requires a nebuliser adapter (P/N: 24
Cyclone with central transer tube
P/N: 47 929 063
For good sensitivity and
stability compromise
HF
kit P/N: 24 031 710
Parallel fow, PEEK/Tefon
P/N: 47 929 024
50 psi argon gas, 1 mL/min
sample uptake
Cyclone, Tefon
P/N: 47 929 031
Limited Volume / Volatile Solvent
kit P/N:
24 072 030 (100 l/min
concentric / mini-cyclo)
Concentric, glass (limited volume)P/N: 47 929 053
50 psi argon gas, 100 L/min
sample uptake
Concentric, glass (volatile solvent)
P/N: 24 072 100
30 psi argon gas, 0.5 mL/min
sample uptake
Cyclone, glassP/N: 31 031 279
Mini-cyclone, glass
P/N: 47 929 049
For sensitivity at low uptake
and very ast washout
Cooled cyclone, glass (Peltier ee
P/N: 24 072 210
For optimum sensitivity
with volatile samples
Organics / Slurries
kit P/N:24 031 610 (0.7 mm id nebuliser)
24 031 600 (1 mm id nebuliser)
Jobin Yvon, Pt needle, Zr nozzle
P/N: 24 031 060
0.7 mm id needle
Jobin Yvon, Stainless Steel needle, Zr nozzle
P/N: 24 031 050
1 mm id needle
(or large particulates, ie wear metals)
Scott, glass
P/N: 31 031 491
Requires the JY nebuliser
adapter (P/N: 24 031 070)
USN nebuliser
P/N: 24 031 650
For aqueous solutions
(gain in sensitivity
by a actor o 5 to 20)
CMA
P/N: 24 072 140
Kit P/N: 24 031 660 (concentric) ;
24 031 670 (parallel)
For simultaneous analysis o hydridesand normal elements
AC
TIVA
S
-
7/28/2019 Activa s Horiba
7/8
7
Torch Observations
Demountable torch
P/N: 21 356 110
Sheath gas system (glass)
P/N: 21 356 040
Specications: high sensitivity, short washout time
Examples o application: routine applications o
clean aqueous or organic solutions (water,)
Demountable torch
P/N: 21 356 110
Sheath gas system (glass)
P/N: 21 356 040
Specications: suitable to high Total Dissolved Solids (TDS), high
precision
Examples o application: waste, sediment, sea water, metals (Cu 30
g/l, precious metals,), alloys, NaCl 300 g/l, LiBO2
20 g/l (usion),
Leachates, cement, Ca sulate require preerably the concentric
nebuliser
Argon humidier (P/N: 24 056 810) is required with the concentric
nebuliser
Demountable torch
P/N: 21 356 110
Alumina inner (P/N: 31 032 312) and outer (P/N: 31
032 313) tubes available i B, Na,Si to measure at
trace levels
Sheath gas system (inert material)P/N: 20 925 160
Specications: suitable to hydrofuoric acid (HF)
Examples o application: reractory samples requiring HF digestion
(Ti base, silica, ashes, lters (air samples))
Demountable torchP/N: 21 356 110
Sheath gas system (glass)
P/N: 21 356 040
Specifcations: suitable to low volume or volatile samples, with optimumsensitivity
Examples o application: biological or nuclear samples (small
amount); ethanol, MIBK, gasoline, acetic acid (volatile)
Demountable torch
P/N: 21 356 110
Sheath gas system (glass)
P/N: 21 356 040
Specifcations: robust and stable operating conditions, high precision
Examples o application: wear metals in oil, uel, biodiesel, particulates
Oxygen Kit (P/N: 24 056 360) is required or
analysis o Na and K at ppb levels in organic samples
AS-500 autosampler
P/N: 44 820 097
(up to 360 samples)
Laser ablation
For solid samples
ax
4 056 140 (ULTIMA 2) ;
6 740 (ACTIVA amily)
mples that solidiy
m temperature (heatingample tube to spray chamber)
-
7/28/2019 Activa s Horiba
8/8Explore the future Automotive Test Systems | Process & Environmental | Medical | Semiconductor | ScientificExplore the future Automotive Test Systems | Process & Environmental | Medical | Semiconductor | Scientific
TECHNICAL SPECIFICATIONSRadio requency, solid-state 40.68 MHz,
water cooled
GenCo water chiller for the generator and the coil
direct exhaust connection or plasma
compartment
Fully demountable torch, 3 mm i.d; aluminainjector, 12 L/min plasma gas, 0.2 L/min
sheath gas
Concentric glass nebulizer, cyclonic glass
spray chamber, 3 channels peristaltic pump
Thermo-regulated, 0.64 meter ocal length,
dual back-to-back gratings, 4343 g/mm and
2400 g/mm used in the 1st order with optical
resolution