TABLA DE DATOS EXPERIMENTALES
COLUMNA I
Tabla 6-2. Datos Experimentales de las Columnas Empacadas.Corrida Columna 1
%R PKgf /cm2
1 30 0.352 40 0.403 50 0.484 60 0.565 70 0.646 80 0.757 90 0.84
COLUMNA II
Tabla 6-2. Datos Experimentales de las Columnas Empacadas.Corrida Columna 2
%R PKgf /cm2
1 30 0.29
2 40 0.303 50 0.324 60 0.355 70 0.396 80 0.427 90 0.46
COLUMNA III
CORRIDA
%R PKgf /cm2
Gvm3/seg
1 30 0.25 0.0000992 40 0.26 0.0001323 50 0.27 0.0001654 60 0.28 0.0001985 70 0.28 0.0002316 80 0.29 0.0002647 90 0.30 0.000297
COLUMNA IV
Tabla 6-2. Datos Experimentales de las Columnas Empacadas.Corrida Columna 4
%R PKgf /cm2
1 30 0.252 40 0.263 50 0.264 60 0.27
5 70 0.286 80 0.297 90 0.30
COLUMNA V
velocidad CORRIDA
Gv ΔP Rem fm Gs ρ
0.048840651
1 0.000099
0.00005
706.071229
7.8291E-08
48.84065121
1000
0.065120868
2 0.000132
0.00007
941.428305
8.2206E-08
65.12086828
1000
0.081401085
3 0.000165
0.00008
1176.78538
7.5159E-08
81.40108535
1000
0.097681302
4 0.000198
0.00014
1412.14246
1.0961E-07
97.68130242
1000
0.113961519
5 0.000231
0.00016
1647.49953
1.0737E-07
113.9615195
1000
0.130241737
6 0.000264
0.00022
1882.85661
1.2918E-07
130.2417366
1000
0.146521954
7 0.000297
0.00028
2118.21369
1.4614E-07
146.5219536
1000
Tabla 6-2. Datos Experimentales de las Columnas Empacadas.Corrida Columna 4 segunda medicion
%R PKgf /cm2
1 30 0.000052 40 0.000073 50 0.00008
4 60 0.000145 70 0.000166 80 0.000227 90 0.00028
TABLA DE RESULTADOS
Tabla de resultados de la columna 1Corrida Gv
litros/minΔP Kgf/cm2
Rem Fm
1) 0.000099 0.000035 2435.9564 1.1817 x10−8
2) 0.000132 0.000040 3247.9419 1.01289 x10−8
3) 0.000165 0.000048 4059.9274 9.7237 x10−9
4) 0.000198 0.000056 4871.9129 9.45359 x10−9
5) 0.000231 0.000064 5683.8984 9.2606 x10−10
6) 0.000264 0.000075 6495.8832 9.4958 x10−9
7) 0.000297 0.000084 7307.8692 9.45359 x10−9
TABLA DE RESULTADOS DE LA COLUMNA 2
CORRIDA Gv
l/min
ΔP
Kgfm2
Rem fm
1 5.94 0.000029 1256.6971 2.73796 x10−7
2 7.92 0.000030 1675.5961 1.59321 x10−7
3 9.90 0.000032 2094.4952 1.08763 x10−7
4 11.88 0.000035 2513.3942 8.26108 x10−8
5 13.86 0.000039 2932.2933 6.76301 x10−8
6 15.84 0.000042 3351.1923 5.57623 x10−8
7 17.82 0.000046 3770.0913 4.82552 x10−8
TABLA DE RESULTADOS DE LA COLUMNA 3
CORRIDA Gv
l/min
ΔP
Kgfm2
Rem fm
1 5.94 0.000025 706.776 8.01496 x10−7
2 7.92 0.000026 942.368 4.68875 x 10−7
3 9.9 0.000027 1177.96 3.11622 x10−7
4 11.88 0.000028 1413.55 2.24419 x10−7
5 13.86 0.000028 1649.14 1.64879 x10−7
6 15.84 0.000029 1884.74 1.30744 x10−7
7 17.82 0.00003 2120.33 1.068666 x10−7
TABLA DE RESULTADOS DE LA COLUMNA 4
CORRIDA Gv
l/min
ΔP
Kgfm2
Rem fm
1 5.94 0.000025 706.776 8.01496 x10−7
2 7.92 0.000026 942.368 4.68875 x 10−7
3 9.9 0.000026 1177.96 3.0008 x10−7
4 11.88 0.000027 1413.55 2.16403 x10−7
5 13.86 0.000028 1649.14 1.64879 x10−7
6 15.84 0.000029 1884.74 1.30744 x10−7
7 17.82 0.000030 2120.33 1.068666 x10−7
TABLA DE RESULTADOS DE LA COLUMNA 4 segunda medición
CORRIDA Gv
l/min
ΔP
Kgfm2
Rem Fm
10.000099 0.00005 0.00005 7.8291E-08
20.000132 0.00007 0.00007 8.2206E-08
30.000165 0.00008 0.00008 7.5159E-08
40.000198 0.00014 0.00014 1.0961E-07
50.000231 0.00016 0.00016 1.0737E-07
60.000264 0.00022 0.00022 1.2918E-07
70.000297 0.00028 0.00028 1.4614E-07
GRÁFICAS
Columna I
2000 3000 4000 5000 6000 7000 80000
0.0000000020.0000000040.0000000060.0000000080.00000001
0.0000000120.000000014
Grafica de fm vs Rem de Columna I
Series2
Rem
fm
4 6 8 10 12 14 16 18 200
0.10.20.30.40.50.60.70.80.9
Grafica de (ΔP)exp vs Gv de Columna I
Series2
Gv
ΔPex
p
Columna II
1000 1500 2000 2500 3000 3500 40000.00E+00
5.00E-08
1.00E-07
1.50E-07
2.00E-07
2.50E-07
3.00E-07
Grafica de fm vs Rem de Columna II
Series2
Rem
fm
4 6 8 10 12 14 16 18 200
0.050.1
0.150.2
0.250.3
0.350.4
0.450.5
Grafica de (ΔP) exp vs Gv de Columna II
Series2
Gv
ΔPex
p
Columna III
600 800 1000 1200 1400 1600 1800 2000 22000.00E+001.00E-072.00E-073.00E-074.00E-075.00E-076.00E-077.00E-078.00E-079.00E-07
Grafica de fm vs Rem de Columna III
Series2
Rem
fm
4 6 8 10 12 14 16 18 200.0000220.0000230.0000240.0000250.0000260.0000270.0000280.0000290.00003
0.000031
Grafica de (ΔP) exp vs Gv de Columna III
Series2
Gv
ΔP e
xp
Columna IV
600 800 1000 1200 1400 1600 1800 2000 22000.00E+001.00E-072.00E-073.00E-074.00E-075.00E-076.00E-077.00E-078.00E-079.00E-07
Grafica de fm vs Rem de Columna IV
Series2
Rem
fm
4 6 8 10 12 14 16 18 200.0000220.0000230.0000240.0000250.0000260.0000270.0000280.0000290.00003
0.000031
Grafica de (ΔP)exp vs Gv de columna IV
Series2
Gv
ΔPex
p
Columna III segunda medición (manómetro de mercurio)
600 800 1000 1200 1400 1600 1800 2000 22000.00E+00
2.00E-07
4.00E-07
6.00E-07
8.00E-07
1.00E-06
1.20E-06
Grafica de fm vs Rem de Columna III medicion 2
Series2
Rem
fm
4 6 8 10 12 14 16 18 200
0.5
1
1.5
2
2.5
3
Grafica de (ΔP)exp vs Gv de Columna III segunda medicion
Series2
Gv
ΔPex
p
Columna IV segunda medición (manómetro de mercurio)
600 800 1000 1200 1400 1600 1800 2000 22000.00E+002.00E-084.00E-086.00E-088.00E-081.00E-071.20E-071.40E-071.60E-07
Grafica de fm vs Rem de Columna IV medicion 2
Series2
Rem
fm
0.00005 0.0001 0.00015 0.0002 0.00025 0.0003 0.000350
0.00005
0.0001
0.00015
0.0002
0.00025
0.0003
Grafica de (ΔP) exp vs Gv de Columna IV medicion 2
Series2
Gv
Δpex
p