catalogo-conductores de cobre aislado

Upload: guillermo-gonzalez

Post on 05-Apr-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    1/18

    Conductores de

    cobre aislados

    Insulated copper

    conductors

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    2/18

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    3/1815

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    These are used in main and branch cir-cuits, indoor and outdoor lighting circuitsor industrial, commercial and residential

    wiring. They can be installed in pipes, con-duits and raceways, in dry or wet locations.

    Construction

    It is a solid or stranded annealed copperconductor insulated with PVC.

    Features

    Maximum operating voltage: 600 V. Maximum operating temperature: 60 C. Resistant to moisture, grease and acids. Flame retardant. Available colors: black, white, red, blue,

    green, yellow and orange.

    Standards

    NTC 1332, UL 83.

    Aplicaciones

    Se usan en circuitos principales o ramalesy en general para instalaciones elctricasinteriores y exteriores de iluminacin, detipo residencial, comercial e industrial.Pueden instalarse en crcamos, ductos ycanalizaciones, en sitios secos o mojados.

    Construccin

    Es un conductor de cobre recocido slidoo cableado, aislado con PVC.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin: 60 C. Resistente a la humedad, grasas y cidos. Retardante a la llama. Colores disponibles: negro, blanco, rojo,

    azul, verde, amarillo y naranja.

    Normas

    NTC 1332, UL 83.

    TW

    TW

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    4/1816

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Alambres y cables TW

    Wires and TW cables

    CalibreConstruccin

    Espesor de aislamiento Dimetro exterior Masa total Capacidad de corrienteN hilos

    SizeConstruction

    Insulation thickness Overall diameter Total mass AmpacityN wires

    AWG / kcmil N mm mils mm in kg/km lb/kft A*

    14 1 0,76 30 3,15 0,12 26 18,1 20

    12 1 0,76 30 3,57 0,14 39 26,5 25

    10 1 0,76 30 4,11 0,16 59 39,4 30

    8 1 1,14 45 5,54 0,22 98 65,6 40

    14 7 0,76 30 3,36 0,13 29 19,4 20

    12 7 0,76 30 3,84 0,15 42 28,3 25

    10 7 0,76 30 4,45 0,18 63 42,1 30

    8 7 1,14 45 5,98 0,24 103 69,9 40

    6 7 1,52 45 7,7 0,27 167,5 112 55

    * Capacidad de corriente permitida en conductores aislados para 60 C: no ms de tres conductores que transportan corriente

    en canalizacin, cable o tierra (directamente enterrados) con base en una temperatura ambiente de 30 C.

    * Allowed ampacities o insulated conductors, 60 C: no more than three current-carrying conductors in raceway, cable ordirectly buried, based on ambient temperature o 30 C.

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    5/1817

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    It is used in main and branch circuits,indoor and outdoor lighting circuits o in-dustrial, commercial and residential wiring.

    They can be installed in pipes, conduitsand raceways, in dry or wet locations.

    Construction

    It's a solid or stranded annealed copperconductor insulated with PVC.

    Features

    Maximum operating voltage: 600 V. Maximum operating temperature: 75 C. Flame retardant. Resistant to moisture, grease and acids. Available colors: black, white, red, blue,

    green, yellow and orange (sizes 14 to 8AWG). Black (sizes 6 AWG and larger).

    Standards

    NTC 1332, UL 83.

    Aplicaciones

    Se usa en circuitos principales o ramales yen general para instalaciones elctricas in-teriores y exteriores de iluminacin, de tiporesidencial, comercial e industrial. Puedeninstalarse en crcamos, ductos y canaliza-ciones, en sitios secos o mojados.

    Construccin

    Es un conductor de cobre recocido slidoo cableado, aislado con PVC.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin: 75 C. Retardante a la llama. Resistente a la humedad, grasas y cidos. Colores disponibles: negro, blanco, rojo,

    azul, verde, amarillo y naranja (calibres14 a 8 AWG). Negro (calibres 6 AWG ymayores).

    Normas

    NTC 1332, UL 83.

    THW

    THW

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    6/1818

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    ThW

    ThW

    CalibreConstruccin

    Espesor de aislamiento Dimetro total Masa total Capacidad de corrienteN hilos

    SizeConstruction

    Insulation thickness Overall diameter Total mass AmpacityN wires

    AWG / kcmil N mm mils mm in kg/km lb/kft A*

    14 1 0,76 30 3,15 0,124 26 17,8 20

    12 1 0,76 30 3,57 0,141 39 26,5 25

    10 1 0,76 30 4,11 0,162 58 39,4 35

    8 1 1,14 45 5,54 0,218 96,5 65,6 50

    14 7 0,76 30 3,36 0,132 28 19,4 20

    12 7 0,76 30 3,84 0,151 41 28,3 25

    10 7 0,76 30 4,45 0,175 61 42,1 35

    8 7 1,14 45 5,98 0,232 103 69,2 50

    6 7 1,52 60 7,7 0,298 165 112 65

    4 7 1,52 60 8,92 0,345 247 167 85

    2 7 1,52 60 10,4 0,403 374 252 115

    1 19 2,03 80 12,5 0,482 485 326 130

    1/0 19 2,03 80 13,5 0,522 596 401 150

    2/0 19 2,03 80 14,7 0,565 736 494 175

    3/0 19 2,03 80 16 0,616 910 611 200

    4/0 19 2,03 80 17,4 0,672 1127 757 230

    250 37 2,41 95 19,3 0,748 1349 903 255

    300 37 2,41 95 28,8 0,801 1599 1069 285

    350 37 2,41 95 22 0,851 1844 1235 310

    400 37 2,41 95 23,2 0,896 2092 1400 335

    500 37 2,41 95 25,4 0,979 2582 1728 380

    600 61 2,79 110 28,2 1,09 3099 2081 420

    700 61 2,79 110 30 1,15 3582 2407 460

    750 61 2,79 110 30,9 1,19 3827 2571 475

    800 61 2,79 110 31,7 1,22 4067 2733 490

    900 61 2,79 110 33,3 1,28 4555 3058 520

    1000 61 2,79 110 34,8 1,34 5033 3382 545

    * Capacidad de corriente permitida en conductores aislados para 75 C: no ms de tres conductores que transportan corrienteen canalizacin cable o tierra (directamente enterrados), con base en una temperatura ambiente de 30 C.

    * Allowed ampacities o insulated conductors, 75 C: no more than three current-carrying conductors in raceway, cable ordirectly buried, based on ambient temperature o 30 C.

    Nota: La inormacin que corresponde al conductor se encuentra en la reerencia cable concntrico de cobre.

    Note: The inormation regarding the conductor can be ound at concentric lay stranded copper conductor reerence.

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    7/1819

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    These are used in main and branch cir-cuits, indoor and outdoor lighting circuitso industrial, commercial and residential

    wiring. They can be installed in pipes, cabletray, conduits and raceways, in dry or wetlocations.

    Construction

    Sot copper conductor, 90 C - PVC insu-lated with nylon sheath.

    Features

    Maximum operating voltage: 600 V. Maximum operating temperature: 90 C

    in moist or dry locations 75 C in wet loca-tions.

    Resistant to moisture, heat, abrasion,chemicals, oil and gasoline.

    Flame retardant. Available colors: black, white, red, blue,

    green, yellow and orange (Sizes 14 to 8AWG). Black (sizes 6 AWG and larger).

    Standards

    NTC 1332, UL 83.

    Aplicaciones

    Se usa en instalaciones elctricas deuerza, control y alumbrados en interiores oexteriores de tipo residencial, comercial eindustrial. Pueden instalarse en crcamos,ductos, bandejas y canalizaciones, en sitiossecos y mojados.

    Construccin

    Conductor de cobre blando, aislado conPVC para 90 C, con chaqueta de nailon.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin: 90 C,

    en ambiente hmedo o seco. 75 C enambiente mojado.

    Resistente a la humedad, al calor, abrasin,elementos qumicos, aceites y gasolina.

    Retardante a la llama. Colores disponibles: negro, blanco, rojo,

    azul, verde, amarillo y naranja (calibres 14 a8 AWG). Negro (calibres 6 AWG y mayores).

    Normas

    NTC 1332, UL 83.

    THHN/THWN

    THHN/THWN

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    8/1820

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Thh/ThW

    Thh/ThW

    Calibre N hilosEspesor

    de aislamientoEspesor chaqueta

    de nailonDimetro exterior Masa total Capacidad de corriente

    Size N wires Insulation thicknessNylon sheath

    thicknessOverall diameter Total mass Ampacity

    AWG / kcmil N mm mils mm mils mm in kg/km lb/kft A*

    14 1 0,38 15 0,10 4 2,69 0,106 23,3 15,6 25

    12 1 0,38 15 0,10 4 3,11 0,123 35,1 23,6 30

    10 1 0,51 20 0,10 4 3,91 0,154 55,9 37,5 40

    8 1 0,76 30 0,13 5 5,15 0,203 91,2 61,3 55

    14 7 0,38 15 0,10 4 2,90 0,114 24,7 16,6 25

    14 19** 0,38 15 0,10 4 2,90 0,113 24,5 16,5 25

    12 7 0,38 15 0,10 4 3,38 0,133 37,2 25,0 30

    12 19** 0,38 15 0,10 4 3,30 0,131 37,0 24,9 30

    10 7 0,51 20 0,10 4 4,26 0,168 59,2 39,8 40

    10 19** 0,51 20 0,10 4 4,19 0,165 58,9 39,6 40

    8 7 0,76 30 0,13 5 5,5 0,216 96,3 64,7 55

    6 7 0,76 30 0,13 5 6,41 0,252 146,0 98,1 75

    4 7 1,02 40 0,15 6 8,18 0,322 233,8 157 95

    2 7 1,02 40 0,15 6 9,65 0,380 358,0 241 130

    1 19 1,27 50 0,18 7 11,2 0,442 454,2 305 150

    1/0 19 1,27 50 0,18 7 12,2 0,482 562,9 378 170

    2/0 19 1,27 50 0,18 7 13,3 0,525 698,8 470 195

    3/0 19 1,27 50 0,18 7 14,6 0,576 869,6 584 225

    4/0 19 1,27 50 0,18 7 16,0 0,632 1083 728 260

    250 37 1,52 60 0,20 8 17,8 0,700 1286 864 290

    300 37 1,52 60 0,20 8 19,1 0,753 1529 1027 320

    350 37 1,52 60 0,20 8 20,4 0,803 1772 1191 350

    400 37 1,52 60 0,20 8 21,5 0,848 2013 1352 380

    500 37 1,52 60 0,20 8 23,7 0,931 2495 1676 430

    600 61 1,78 70 0,23 9 26,2 1,032 3001 2017 475

    750 61 1,78 70 0,23 9 28,8 1,134 3720 2500 535

    1000 61 1,78 70 0,23 9 32,6 1,283 4914 3302 615

    * Capacidad de corriente permitida en conductores aislados para 90 C: no ms de tres conductores que transportan corrienteen canalizacin, cable o tierra (directamente enterrados) con base en una temperatura ambiente de 30 C.

    * Allowed ampacities o insulated conductors, 90 C: no more than three current-carrying conductors in raceway, cable ordirectly buried, based on ambient temperature o 30 C.

    ** Cableado unidirecional combinado de 19 hilos.

    ** 19 wire combination unilay stranded conductors.

    Nota: La inormacin que corresponde al conductor se encuentra en la reerencia cable concntrico de cobre.

    Note: The inormation regarding the conductor can be ound at concentric lay stranded copper conductor reerence.

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    9/1821

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    It is used in electric installations o powercircuit and indoor and/or outdoor distribu-tion.

    Construction

    It is a sot copper conductor insulated withXLPE-FR.

    Features

    Maximum operating voltage: 600 V. Maximum operating temperature: 90 C

    in dry or wet locations. Resistant to moisture, heat, abrasion,

    chemical, acid and oil. Flame retardant. Available color: black.

    Standards

    NTC 3277, UL 44.

    Aplicaciones

    Se usa en instalaciones elctricas de cir-cuitos de uerza y distribucin en interiores

    y exteriores.

    Construccin

    Es un conductor de cobre blando, aisladocon XLPE-FR.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin: 90 C

    en sitios secos o mojados. Resistente a la humedad, al calor, a la

    abrasin, a elementos qumicos, cidos yaceites.

    Retardante a la llama. Color disponible: negro.

    Normas

    NTC 3277, UL 44.

    XHHW-2

    XHHW-2

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    10/1822

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    XhhW-2

    XhhW-2

    CalibreConstruccin Espesor de

    aislamientoDimetro exterior Masa total Capacidad de corriente

    N de hilos

    SizeConstruction

    Insulation thickness Overall diameter Total mass AmpacityN wires

    AWG / kcmil N mm mils mm in kg/km lb/kft A* A**8 7 1,14 45 5,98 0,235 97,4 65,5 55 80

    6 7 1,14 45 6,89 0,271 146 98,3 75 105

    4 7 1,14 45 8,09 0,318 224 150 95 140

    2 7 1,14 45 9,56 0,376 344 231 130 190

    1 19 1,40 55 11,09 0,437 436 293 150 220

    1/0 19 1,40 55 12,11 0,477 542 364 170 260

    2/0 19 1,40 55 13,20 0,52 676 454 195 300

    3/0 19 1,40 55 14,49 0,571 844 567 225 350

    4/0 19 1,40 55 15,92 0,627 1054 708 260 405

    250 37 1,65 65 17,61 0,693 1249 840 290 455

    300 37 1,65 65 18,95 0,746 1489 1000 320 505

    350 37 1,65 65 20,22 0,796 1729 1161 350 570400 37 1,65 65 21,36 0,841 1966 1321 380 615

    500 37 1,65 65 23,47 0,924 2442 1641 430 700

    750 61 2,03 80 29,56 1,16 3668 2465 535 885

    1000 61 2,03 80 33,43 1,32 4854 3262 615 1055

    * Capacidad de corriente permitida en conductores aislados para 90 C: no ms de tres conductores que transportan corrienteen canalizacin, cable o tierra (directamente enterrados) con base en una temperatura ambiente de 30 C.

    * Allowed ampacities o insulated conductors, 90 C: no more than three current-carrying conductors in raceway, cable, ordirect buried, based on ambient temperature o 30 C.

    ** Capacidad de corriente permitida en conductores sencillos al aire libre, temperatura ambiente de 30 C, temperatura mxima

    en el conductor de 90 C.

    ** Allowed ampacities o single insulated conductors, 90 C, in open air, based on ambient air temperature o 30 C.

    Nota: La inormacin que corresponde al conductor se encuentra en la reerencia cable concntrico de cobre.

    Note: The inormation regarding the conductor can be ound at concentric lay stranded copper conductor reerence.

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    11/1823

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    RHW-2 and USE-2 cables are used inindoor and outdoor power and distributioncircuit wiring. The USE cable is suitable orunderground, directly buried connections.

    Construction

    It is a sot copper conductor. RHW-2 or

    USE-2 cables are insulated with XLPE-FR.USE cables are insulated with XLPE-UV,

    which is not ame retardant.

    Features

    Maximum operating voltage: 600 V. RHW-2 or USE-2 maximum operating

    temperature: 90 C in dry or wet locations.USE: 90 C in dry or moist locations and75 C in wet locations.

    Resistant to moisture, heat, abrasion, tochemicals, acids and oil.

    Available color: black.

    Standards

    RHW-2: NTC 3277, UL 44.USE-2 and USE: NTC 4564, UL 854.

    Aplicaciones

    Los cables RHW-2 o USE-2 se usan parainstalaciones de circuitos de uerza ydistribucin, en interiores o exteriores. Elcable USE es adecuado para acometidassubterrneas en enterramiento directo.

    Construccin

    Es un conductor de cobre blando. Loscables RHW-2 y USE-2 son aislados con

    XLPE-FR. Los cables USE son aislados conXLPE-UV, no retardante a la llama.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin RHW-2

    o USE-2: 90 C en sitios secos o mojados.USE: 90 C en sitios secos o hmedos yen sitios mojados de 75 C.

    Resistente a la humedad, al calor, a la abra-sin, a elementos qumicos, cidos y aceites.

    Color disponible: negro.

    Normas

    RHW-2: NTC 3277, UL 44.USE-2 y USE: NTC 4564, UL 854.

    RHW-2/USE-2/USE

    RHW-2/USE-2/USE

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    12/18

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    13/1825

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    Suitable or overhead lines, distribution andlighting circuits. Installation in pipes, conduits,raceways and directly buried.

    Construction

    It is a sot copper conductor insulated withXLPE or PE with a PVC jacket. Aluminum

    conductors or 2000 V operating voltagecables can be manuactured on demand.

    Features

    Maximum operating voltage: 600 V. Maximum operating temperature: 90 C

    (XLPE insulation) and 75 C (PE insulation). Flame retardant PVC jacket. Optimal electrical insulation characteristics

    o the XLPE and PE are similar to PVC.

    Standards

    ICEA S-95-658.

    Aplicaciones

    Se usa en lneas areas de distribucin eiluminacin. Indicado para instalar en duc-tos, canalizaciones y enterramiento directo.

    Construccin

    Es un conductor de cobre temple blandoaislado con XLPE o PE y chaqueta exterior

    de PVC. Cables con conductor de aluminioo para tensin de operacin de 2.000 V sepueden abricar bajo pedido.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin: 90 C

    para cable aislado con XLPE y 75 C paracable aislado con PE.

    Chaqueta en PVC retardante a la llama. ptimas caractersticas elctricas del

    aislamiento de XLPE o PE con las propie-dades del PVC.

    Normas

    ICEA S-95-658.

    TTU

    TTU

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    14/1826

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    TTU

    TTU

    Calibre N hilosEspesor deaislamiento

    Espesor dechaqueta

    Dimetro exterior Masa total

    Capacidad de corriente

    XLPE PE XLPE PE

    90 C 75 C 90 C 75 C

    Size N wiresInsulation

    thicknessJacket thickness Overall diameter Total mass

    Ampacity

    XLPE PE XLPE PE

    90 C 75 C 90 C 75 C

    AWG /kcmil

    N mm mils mm mils mm in kg/km lb/kft A(1)* A(2)* A(3)* A(4)*

    12 7 0,76 30 0,38 15 4,6 0,181 45 30,0 30 25 40 35

    10 7 0,76 30 0,38 15 5,2 0,205 65 43,8 40 35 55 50

    8 7 1,14 45 0,38 15 6,7 0,262 104 69,9 55 50 80 70

    6 7 1,14 45 0,76 30 8,3 0,328 168 113 75 65 105 95

    4 7 1,14 45 0,76 30 9,5 0,375 249 167 95 85 140 125

    2 7 1,14 45 0,76 30 11,0 0,433 374 252 130 115 190 170

    1 19 1,40 55 1,14 45 13,3 0,522 490 329 150 130 220 195

    1/0 19 1,40 55 1,14 45 14,3 0,562 600 404 170 150 260 230

    2/0 19 1,40 55 1,14 45 15,4 0,605 739 497 195 175 300 265

    3/0 19 1,40 55 1,14 45 16,7 0,656 912 613 225 200 350 310

    4/0 19 1,40 55 1,14 45 18,1 0,712 1129 759 260 230 405 360

    250 37 1,65 65 1,65 65 20,8 0,818 1374 924 290 225 455 405

    300 37 1,65 65 1,65 65 22,1 0,871 1623 1090 320 285 505 445

    350 37 1,65 65 1,65 65 23,4 0,921 1871 1257 350 310 570 505

    400 37 1,65 65 1,65 65 24,5 0,966 2115 1422 380 335 615 545

    500 37 1,65 65 1,65 65 26,6 1,05 2605 1751 430 380 700 620

    600 61 2,03 80 1,65 65 29,4 1,16 3120 2097 475 420 780 690

    750 61 2,03 80 1,65 65 32,0 1,26 3849 2586 535 475 885 785

    800 61 2,03 80 1,65 65 32,8 1,29 4090 2748 555 490 920 815

    900 61 2,03 80 1,65 65 34,3 1,35 4573 3073 585 520 985 870

    1000 61 2,03 80 1,65 65 35,7 1,41 5056 3397 615 545 1055 935

    A(1), A(2): Capacidad de corriente permitida en conductores aislados para 90 C o 75 C: no ms de tres conductores quetransportan corriente en canalizacin, cable o tierra (directamente enterrados) con base en una temperatura ambiente de 30 C.

    A(1), A(2) Allowed ampacities o insulated conductors, 90 C or 75 C: no more than three current-carrying conductors in ra-ceway, duct, or directly buried, based on ambient temperature o 30 C.

    A(3), A(4): Capacidad de corriente permitida en conductores monopolares para 90 C o 75 C al aire libre con base en unatemperatura ambiente de 30 C.

    A(3 ), A(4): A llowed ampacities o single insulated conductors, 90 C or 75 C, in ree air, based on ambient air temperature o30 C.

    Nota: La inormacin que corresponde al conductor se encuentra en la reerencia cable concntrico de cobre.Note: The inormation regarding the conductor can be ound at concentric lay stranded copper conductor reerence.

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    15/1827

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    Entrance cable connected rom the distribu-tion circuit to the meter panel.

    Construction

    It is a sot copper conductor, insulated withXLPE 90 C or PE 75 C with two phaselaid parallel which are covered by a PVC

    fller. Over it, there is a neutral conductor(wires o sot copper in a concentric heli-coidal orm) and a polyester tape to protectthe concentric neutral wires. The black

    jacket o PVC, PE or XLPE is weather-resis-tant with a nylon thread. Also manuactured

    with aluminum alloy series 8000.

    Features

    Maximum operating voltage: 600 V. Maximum operating temperature: 90 C

    (XLPE insulation) and 75 C (PE insulation). It prevents power thet because o its

    special construction with concentric neutralconductor.

    Standards

    NTC 4564, UL 854, ICEA S-95-658.

    Aplicaciones

    Cable de entrada que se conecta desde elcircuito de distribucin hasta el medidor.

    Construccin

    Es un conductor de cobre blando, conaislamiento XLPE 90 C o PE 75 C con dosases dispuestas paralelamente, las cuales

    son cubiertas por un relleno en PVC. Enci-ma de ste va el conductor neutro (hilos decobre blando en orma helicoidal concntri-ca) y una cinta de polister para proteccindel neutro concntrico. Chaqueta de PE,

    XLPE o PVC negro tipo intemperie. Contieneun hilo de nailon entre el conductor neutro yla chaqueta para el rasgado. Se abrica tam-bin con aleacin de aluminio serie 8000.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin: 90 C

    para el cable aislado con XLPE, 75 C conaislamiento en PE.

    Difculta el raude de energa por su cons-truccin especial con neutro concntrico.

    Normas

    NTC 4564, UL 854, ICEA S-95-658.

    TSEC confguracin plana

    con neutro concntrico

    TSEC at confguration

    with concentric neutral

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    16/1828

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    TSEC conguracin plana con neutro concntrico

    TSEC fat conguration wit concentric neutral

    Fases +neutro

    Espesor deaislamiento

    Construccin conductorneutro

    (N hilos x f)

    Espesor dechaqueta

    Dimensiones totales Masa totalCapacidad de

    corriente

    Phases +

    neutral

    Insulation

    thickness

    Neutral conductor

    construction(N wires x f)

    Jacket

    thickness Overall dimensions Total mass

    Ampacity

    75 C 90 C

    AWG mm mils N mm mils mm mils mm mm in in kg/km lb/kft A* A**

    2 x 8 + 8 1,14 45 41 x 0,511 20,1 1,52 60 10,4 x 16,3 0,41 x 0,64 363 244 50 55

    2 x 8 + 10 1,14 45 42 x 0,404 15,9 1,52 60 10,2 x 16,1 0,40 x 0,63 327 220 50 55

    2 x 6 + 8 1,14 45 66 x 0,404 15,9 1,52 60 11,0 x 18,0 0,43 x 0,71 467 314 65 75

    2 x 6 + 6 1,14 45 41 x 0,643 25,3 1,52 60 11,4 x 18,5 0,45 x 0,73 520 349 65 75

    2 x 4 + 6 1,14 45 66 x 0,511 20,1 2,03 80 13,4 x 21,6 0,53 x 0,85 726 488 85 95

    2 x 4 + 4 1,14 45 42 x 0,810 31,9 2,03 80 14,0 x 22,1 0,55 x 0,87 814 547 85 95

    * Capacidad de corriente permitida basada en una temperatura de 75 C en el conductor y 30 C de temperatura ambiente.

    * Allowed ampacity based on 75 C o the conductor and 30 C ambient temperature.

    ** Capacidad de corriente permitida basada en una temperatura de 90 C en el conductor y 30 C de temperatura ambiente.

    ** Allowed ampacity based on 90 C o the conductor and 30 C ambient temperature.

    Nota: La inormacin que corresponde al conductor de ase se encuentra en la reerencia cable concntrico de cobre.

    Note: The inormation regarding the phase conductor can be ound at concentric lay stranded copper conductor reerence.

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    17/1829

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    Applications

    It is used as an entrance cable, connectedrom the distribution circuit to the meterpanel.

    Construction

    It is a sot copper conductor, with insulationin XLPE 90 C or PE 75 C. With one, two

    or more phases assembled and coveredby a PVC fller. Over the fller is helicoidallyapplied a neutral conductor ormed by sotcopper wires. PVC, PE or XLPE overall

    jacket is weather-resistant. There is a nylonthread between the concentric neutral con-ductor and the jacket. Also manuactured

    with aluminum alloy 8000 series.

    Features

    Maximum operating voltage: 600 V. Maximum operating temperature: 90 C

    (XLPE insulation). 75 C (PE insulation). It prevents power thet because o its

    special construction with concentric neutralconductor.

    Standards

    UL 854, ICEA S-95-658.

    Aplicaciones

    Se usa como cable de entrada que seconecta desde el circuito de distribucinhasta el medidor.

    Construccin

    Es un conductor de cobre blando conaislamiento de PE 75 C o XLPE 90 C. Con

    uno, dos o ms ases ensambladas y cu-biertas con un relleno de PVC. Sobre este

    va el conductor neutro (hilos de cobre blan-do en orma helicoidal concntrica). Cha-queta exterior de PE, XLPE o PVC negrotipo intemperie. Contiene un hilo de nailonentre el conductor neutro y la chaqueta parael rasgado. Se abrica tambin en aleacinde aluminio serie 8000.

    Caractersticas

    Tensin mxima de operacin: 600 V. Temperatura mxima de operacin: 90 C

    para el cable aislado con XLPE 75 C parael cable aislado con PE.

    Evita el raude de energa por su cons-truccin especial con neutro concntrico.

    Normas

    UL 854, ICEA S-95-658.

    TSEC confguracin redonda

    con neutro concntrico

    TSEC round confguration

    with concentric neutral

  • 7/31/2019 Catalogo-conductores de Cobre Aislado

    18/18

    Procables S.A. C.I. se reserva el derecho de modicar el contenido del catlogo sin previo aviso. / Procables S.A. C.I. reserves to itself the right to change the content of the catalogue without prior notice.

    TSEC conguracin redonda con neutro concntrico

    TSEC concentric neutral round cable

    Fases +neutro

    Espesor deaislamiento

    Construccin conductor neutro(N hilos x )

    Espesor dechaqueta

    Dimetro exterior Masa totalCapacidad de

    corriente

    Phases +neutral

    Insulationthickness

    Neutral conductor construction(N wires x )

    Jacket thickness Overall diameter Total massAmpacity

    75 C 90 C

    AWG mm mils wires x mm mils mm mils mm in kg/km lb/kft A* A**

    1 x 8 + 8 1,14 45 26 x 0,643 25,3 1,14 45 9,6 0,38 213 143 50 55

    2 x 8 + 8 1,14 45 66 x 0,404 15,9 1,14 45 16,7 0,66 458 308 50 55

    3 x 8 + 10 1,14 45 42 x 0,404 15,9 1,52 60 18,5 0,73 582 391 50 55

    3 x 8 + 8 1,14 45 41 x 0,511 20,1 1,52 60 18,7 0,74 613 412 50 55

    2 x 6 + 6 1,14 45 66 x 0,51 20,1 2,03 80 19,6 0,77 671 451 65 75

    2 x 4 + 4 1,14 45 66 x 0,643 25,3 2,03 80 22,2 0,88 967 650 85 95

    * Capacidad de corriente permitida basada en una temperatura de 75 C en el conductor y 30 C de temperatura ambiente.

    * Allowed ampacity based on 75 C o the conductor and 30 C ambient temperature.

    ** Capacidad de corriente permitida basada en una temperatura de 90 C en el conductor y 30 C de temperatura ambiente.

    ** Allowed ampacity based on 90 C o the conductor and 30 C ambient temperature.

    Nota: La inormacin que corresponde al conductor de ase se encuentra en la reerencia cable concntrico de cobre.

    Note: The inormation regarding the phase conductor can be ound at concentric lay stranded copper conductor reerence.