Innovative Solutions for Non IntrusiveInspecting of Insulated Objects
ing. Mark de WaardProject Manager
Applus RTD
-
8/17/2019 RTD Incotest Presentation
2/27
Contents
Introduction Applus RTD
Non Intrusive Inspection
Principle of RTD-INCOTEST ®
Top 5 Applications
| 2
-
8/17/2019 RTD Incotest Presentation
3/27
Introduction Applus RTD
RTD was Founded in 1937 in the NetherlandsPart of the Applus Group in 2006Specialized in Non-Destructive Testing (NDT) andInspection Solutions
| 3
-
8/17/2019 RTD Incotest Presentation
4/27
Introduction Applus RTD
| 4
-
8/17/2019 RTD Incotest Presentation
5/27
Examine installation parts whenever you want while in-service
No unnecessary destruction of insulation or other
Status on interior/exterior of equipment
Know what is happening before a maintenance shutdown
| 5
Non-Intrusive means
-
8/17/2019 RTD Incotest Presentation
6/27
| 6
Last minutedefects are found
ExtendeddowntimePlanned downtime
Early in-serviceinspection
Downtime is shorter as you know exactlywhere to look without last minute surprises
Common approach
The Applus RTD approach
Minimizing Downtime
-
8/17/2019 RTD Incotest Presentation
7/27
-
8/17/2019 RTD Incotest Presentation
8/27
In-Service Spot Check
Alternative RTD-INCOTEST®
? Average Wall Thickness screening in one single areaMapping according to gridOnly global degradation; detection of local corrosion is
sheer luck
| 8
-
8/17/2019 RTD Incotest Presentation
9/27
Principle of RTD-INCOTEST ®
IN sulated COmponent TEST ing,by means of Pulsed Eddy Current (PEC)
| 9
-
8/17/2019 RTD Incotest Presentation
10/27
Principle of RTD-INCOTEST ®
Low Alloy Carbon Steel (ferromagnetic)
Wall Thickness 6-65 mm
Insulation Thickness
-
8/17/2019 RTD Incotest Presentation
11/27
Principle of RTD-INCOTEST ®
Sensor selection diagram - none, alu & SS sheeting
0
10
20
30
40
50
60
70
0 25 50 75 100 125 150 175 200 225 250 _ _ _ _ MKI Lift-off [mm] _____ MKII
W a l
l t h i c k n e s s
[ m m
]
V1.0-02
P0.5-1
P1.5-04
P0.25-0
| 11
-
8/17/2019 RTD Incotest Presentation
12/27
Standard probes
50mm
Principle of RTD-INCOTEST ®
| 12
-
8/17/2019 RTD Incotest Presentation
13/27
Principle of RTD-INCOTEST ®
| 13
Time
-
8/17/2019 RTD Incotest Presentation
14/27
Principle of RTD-INCOTEST ®
| 14
-
8/17/2019 RTD Incotest Presentation
15/27
Principle of RTD-INCOTEST ®
| 15
InspectionGrid
AWT [%]
Eddy CurrentDecay
Evaluation
Numbers
-
8/17/2019 RTD Incotest Presentation
16/27
Top 5 Applications
Sphere Legs
Piping
Vessels and Tanks
Columns
Sub Sea Applications
| 16
-
8/17/2019 RTD Incotest Presentation
17/27
Top 5 Applications – Sphere Legs
| 17
-
8/17/2019 RTD Incotest Presentation
18/27
Top 5 Applications – Sphere Legs
| 18
-
8/17/2019 RTD Incotest Presentation
19/27
Top 5 Applications – Piping
| 19
-
8/17/2019 RTD Incotest Presentation
20/27
Top 5 Applications – Vessels and Tanks
| 20
-
8/17/2019 RTD Incotest Presentation
21/27
Top 5 Applications – Columns
| 21
-
8/17/2019 RTD Incotest Presentation
22/27
Top 5 Applications – Sub Sea
| 22
Off-shore = On-shore for RTD-INCOTEST ®
-
8/17/2019 RTD Incotest Presentation
23/27
Top 5 Applications – Sub Sea
| 23
-
8/17/2019 RTD Incotest Presentation
24/27
Conventional
Down timeScaffolding
Insulation RemovalSurface preperationInspection
Apply Insulation
| 24
RTD-INCOTEST ®
On streamRope Access orExtension ToolDirectly on Insulation
Why RTD-INCOTEST ®
-
8/17/2019 RTD Incotest Presentation
25/27
Screening and follow-up
| 25
False Call
Severe Corrosion !
-
8/17/2019 RTD Incotest Presentation
26/27
Reporting RTD-INCOTEST ®
| 26
-
8/17/2019 RTD Incotest Presentation
27/27
Corrosion Detection
Screening Tool
No Direct Surface Contact Needed
No Surface Preparation Needed
On-Stream
Saves Time, Costs * and Risk