Energy Efficient Datacenters
Smart IT solutions
Smart Energy & Smart Grids
Supported by our Alliance Partners
CONSORTIUM GREEN IT REGIO AMSTERDAM
DE HOEVEELHEID CONTENT GROEIT
Uitgekomen voorspelling Cisco in 2009:
“In 2012 produceren 20 huishoudens meer data dan de hele capaciteit van het internet in 1995”
De speelduur van 1 maand aan nieuwe Youtube content?
300 jaar!
CONTENT KOST ENERGIE
(Met dank aan John Summers, University of Leeds)
Volgens Time magazine kost het 0,0002kWh om 1 minuut video te streamen van een Youtube datacenter...
Volgens Jay Walker’s TED talk kost het downloaden van 1MB data via het internet 0,01kWh energie
De devices waarmee video gestreamd wordt, gebruiken gemiddeld 0.001kWh for 1 minuut video streamen
Gangnam Style’s 25000M downloads van 17MB gedurende 4 minuten streamen kost in totaal 487 GWh energie
WAT BETEKENT DIT VOOR DATACENTERS?
• Voortdurende groei in vraag• Cruciaal voor de digitale economie• “Always on” is een vereiste: 24x7xaltijd• Druk om energiegebruik te beperken: kosten• Druk om CO₂-uitstoot te beperken: duurzaam
Een jonge, multi-disciplinaire industrie
IN VERSCHILLENDE VORMEN EN MATEN
Colocation
• Levering van ruimte, stroom en communicatie, inclusief de racks
• Remote diensten
Managed Hosting / Cloud
• Levering van een werkend system, inclusief evt applicaties
Wholesale
• Levering van ruimte - geen racks
• Soms niet meer dan alleen het gebouw
Private datacenters
• Faciliteit met één eigenaar
• Serverruimtes• Grote datacenters• “Bezemkasten”
DATACENTERS IN DE REGIO
Datacenters in de regio (bron: datacentergids)Rode circels geven gebieden met hoge capaciteit aan
WARMTE MOET HET DATACENTER UIT
Source: APC Schneider Whitepaper 59, revision 2
Source: ASHRAE
● Processor (onbelast): 40-50 graden● Processor (belast): 60-75 graden (of meer)● In praktijk:
○ Lucht uit DC niet warmer dan 28 graden
HOT AND COLD ISLES
• Al dan niet gebruikmakend van koele lucht in de omgeving (met CRAH units)• Warme lucht uit een rack in de praktijk niet boven 33 graden (delta-T: 10-12,5 graden)• Warm water in de praktijk niet boven 22 graden (met delta-T van 10 graden: 18 graden
water)
VRIJE KOELING IN DE EU
• Vrije koeling kan in Nederland (en in de EU) meer dan 8500 uur per jaar toegepast worden
• Koelsystemen varieren: • Afstand water tot warmtebron• Methoden voor luchtcirculatie• ...
• Inzet thermodynamica om luchtstroom te optimaliseren
Maar:
Uiteindelijk is lucht een ISOLATIEMIDDEL voor warmte, geen transportmiddel
OLIEBADKOELING ALS WAARDIG ALTERNATIEF?
Niche-product: geen standaard in de sector; niet geschikt voor ieder datacenter: eerder voor supercomputing en cloud computing dan voor
co-location datacenters
EnergyFootprint
AECORSIS IMMERSED COMPUTING 22
2010 2013 2016 Aecorsis
DC Efficiency PUE 1,6 PUE 1,3 PUE 1,1 PUE 1,1
Energy Reduction 0% 10% 20% 40%
Conventional technologies
+
+
● Processor (onbelast): 40-50 graden● Processor (belast): 60-75 graden (of meer)● Water uit warmtewisselaar: 40-45 graden
Source: AECORSIS
Amsterdam Smart City Meeting 24Amsterdam, NL 04/02/2016
Project FP7 – SMARTCITIES – 2013 Grant Agreement n°: 609211
Green nEtworked data centres as energY proSumErs in smaRt city environments
WARMTENETTEN MEETING | IJMUIDEN, NL | 12 FEB 2016
Enabling energy efficient data centres
integration in smart grids and cities
GEYSER - TOEGANKELIJK MAKEN VAN FLEXIBILITEIT
http://193.226.5.79/second-prototype-web-interface/
Decentralized flexibility via:
✓ demand-side management strategies (like load/demand flexibility and active energy consumers/prosumers engagement)
✓ supply-side management (local decentralized energy storage and/or integration with other energy or resource networks)
✓ a combination of the above
Data Centres as Multi-resource Hubs to optimize Smart City Resource Management
GEYSER: ENERGY FLEXIBILITY AT LOCAL LEVEL
GEYSER builds its flexibility offer to the interested stakeholders (local DSOs, retailers, ESCOs, energy traders) though uniquely combining and optimizing internal (back up and intermittent renewable) generation capability with internal energy (either thermal or electric) storage and computational workload shifting techniques
For DCsData Centre Energy Management linked to local grid and energy markets
For DSOsRegulationReserveSchedulingReactive Power Control
For ESCos & Traders Energy Marketplace Management
For Smart CitiesEnergy Portfolio Planning & Management
A new, data centre initiated business stream
Providing Coordination, Exploiting Flexibility, Stabilizing Grid
Supporting a more competitive DC industry
BUSINESSCASE BIJ COMBINATIE MAATREGELEN
Bron: energie-efficiënt herinrichten van computerruimtes en datacenters
HERGEBRUIK RESTWARMTE IN EEN GEBOUW
Bron: energie-efficiënt herinrichten van computerruimtes en datacenters
Uitgaande lucht
Ingaande lucht
WKO
Uitgaande lucht
Ingaande lucht
DC
Warmteterugwinning en
hergebruik warmte
Investering < 1000 €/kW ictBesparing op
energiekosten580 €/kW ict
Emissie reductie
van CO2
Ca. 3 ton/kW ict
● Hergebruik van restwarmte datacenter om kantoorruimtes in het gebouw zelf op te warmen kan een positieve casus opleveren
● Rekenvoorbeeld ○ Kantoor van 4000m2 ○ Datacenter van 150m2, 40kW: kleinschalig
Interxion Kista, Stockholm
• Bestaande aansluiting op koudenet
• Koeling vanuit koudenet• Koeltoren als backup
• 24 graden warmte via koudenet naar heatpumps stadsverwarming
Bron: Open District Heatinghttp://www.opendistrictheating.com/pilot/interxion_kista/
Maatwerk: inpassing bestaand datacenter in warmte- en koudenetProceskoeling en heat recovery als een service van Fortum Värme
De casus werkt doordat een combinatie van maatregelen een bestaand datacenter verbeterd heeft
Bahnhof Thule, Stockholm
• Datacenter van een cloud provider / ISP• Was eerst datacenter van een
verzekeraar• Heatpumps voeden in warmtenet en
koudenet• Koud water wordt kouder gemaakt,
warm water warmer• Tegen lage kosten afkoelen van warm
water uit DCBron: Open District Heatinghttp://www.opendistrictheating.com/pilot/bahnhof_thule/
Maatwerk: marktwerking zorgt ervoor dat bij voldoende koude dagen (7 graden max) warmtelevering profijt geeft
Mede mogelijk door goede samenwerking leverancier stadswarmte en DC
WARMTEPOMPEN
Uitgangspunt:
• Datacenter genereert warmte (die verdwijnt)• Koelmachine genereert koude (koeling van top)• Eventueel: WKO buffert warmte en koude
Vraag:
Kunnen warmtepompen bijdragen aan de haalbaarheid van een koppeling tussen datacenters en koude- en warmtenetten?
• Wat zijn de relevante voorwaarden?• Waar?